Novel efficient deep reinforcement learning-based load frequency control for isolated microgrid

This study introduces a Learning-based Load Frequency Control (LB-LFC) approach to manage the challenges posed by renewable energy’s intermittency in microgrids, which often causes load disturbances, frequency fluctuations, and higher generation costs. The LB-LFC method employs reinforcement learning to balance generation costs and frequency stability effectively. In addition, a novel sort replay actor critic technique is proposed, leveraging the deep deterministic policy gradient algorithm and sort experience replay to enhance control efficiency and robustness. This dual-objective control strategy not only improves frequency management but also aims to reduce generation expenses. The effectiveness of this approach is validated through simulations on the isolated microgrid load frequency control model of China Southern Grid.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-02-01
DOI
https://doi.org/10.1063/5.0240774
Citations
4
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
2.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel efficient deep reinforcement learning-based load frequency control for isolated microgrid

Yitao Zhao, Yijing Zhang, Jianlin Tang, Xin Shen et al.
4 citations
AIP Advances
Frequency Control in Power Systems
2.92
article

Novel efficient deep reinforcement learning-based load frequency control for isolated microgrid

Yitao Zhao, Yijing Zhang, Jianlin Tang, Xin Shen, Jiahao Li, Xiaoming Lin, Bin Qian
article en
4 citations

Abstract

This study introduces a Learning-based Load Frequency Control (LB-LFC) approach to manage the challenges posed by renewable energy’s intermittency in microgrids, which often causes load disturbances, frequency fluctuations, and higher generation costs. The LB-LFC method employs reinforcement learning to balance generation costs and frequency stability effectively. In addition, a novel sort replay actor critic technique is proposed, leveraging the deep deterministic policy gradient algorithm and sort experience replay to enhance control efficiency and robustness. This dual-objective control strategy not only improves frequency management but also aims to reduce generation expenses. The effectiveness of this approach is validated through simulations on the isolated microgrid load frequency control model of China Southern Grid.

AIP AdvancesVol. 15(2)
Electric Power Research Institute (US), Power Grid Corporation (India) (IN)
Guangdong Power Grid Company
Openalex Percentile: Top 10%
Frequency Control in Power Systems
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.