Femtosecond laser-induced plasma filaments for beam-driven plasma wakefield acceleration

We describe the generation of plasma filaments for application in plasma-based particle accelerators. The complete characterization of a plasma filament generated by a low-energy self-guided femtosecond laser pulse is studied experimentally and theoretically in a low-pressure nitrogen gas environment. For this purpose, we adopted a spectroscopic methodology to measure the plasma density and electron temperature. In addition to this, we also employed a side-imaging technique to retrieve the plasma column sizes (length and diameter). The measurements show the stable generation of a ≈4-cm-long plasma filament with ≈300µm diameter. The peak plasma density and temperature are n_{e}≈10^{16}cm^{-3} and T_{e}≈1.3eV, respectively, with a decay time of approximately 8 ns. We show that the experimental results are in agreement with numerical simulations in terms of filament size and density decay time.

Authors

Institutions

Publication Details

Journal
Physical review. E
Published
2025-02-18
DOI
https://doi.org/10.1103/physreve.111.025202
Citations
1
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
1.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Femtosecond laser-induced plasma filaments for beam-driven plasma wakefield acceleration

M. Ferrario, M. Galletti, A. Biagioni, F. Villa et al.
1 citations
Physical review. E
Laser-Plasma Interactions and Diagnostics
1.87
article

Femtosecond laser-induced plasma filaments for beam-driven plasma wakefield acceleration

M. Ferrario, M. Galletti, A. Biagioni, F. Villa, L. Verra, A. Zigler, R. Pompili, L. Crincoli, Romain Demitra
article en
1 citations

Abstract

We describe the generation of plasma filaments for application in plasma-based particle accelerators. The complete characterization of a plasma filament generated by a low-energy self-guided femtosecond laser pulse is studied experimentally and theoretically in a low-pressure nitrogen gas environment. For this purpose, we adopted a spectroscopic methodology to measure the plasma density and electron temperature. In addition to this, we also employed a side-imaging technique to retrieve the plasma column sizes (length and diameter). The measurements show the stable generation of a ≈4-cm-long plasma filament with ≈300µm diameter. The peak plasma density and temperature are n_{e}≈10^{16}cm^{-3} and T_{e}≈1.3eV, respectively, with a decay time of approximately 8 ns. We show that the experimental results are in agreement with numerical simulations in terms of filament size and density decay time.

Physical review. EVol. 111(2)
University of Rome Tor Vergata (IT), Hebrew College (US), Hebrew University of Jerusalem (IL), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati (IT), Sapienza University of Rome (IT)
European Commission
Affordable and clean energy
Openalex Percentile: Top 16%
Laser-Plasma Interactions and Diagnostics
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Femtosecond laser-induced plasma filaments for beam-driven plasma wakefield acceleration — M. Ferrario, M. Galletti, et al. · Physical review. E (2025) | TGRS Research Map | TGRS