Voltage Control Partitioning Method Based on Weighted Fast-Newman for Ultra High Voltage Direct Current Power Grid

With the infeed UHV-DC merges into the power grid, the division of voltage control partitioning is more challenging, which is an important step in the secondary voltage control of power system. In this paper, the infeed UHV-DC node is equivalent to a reactive power supply, the weighted Fast-Newman algorithm is used to merge the reactive power sources through the maximum distance difference degree. The proposed method makes load nodes be divided with voltage reactive sensitivity and the average power factor. Which not only reflects the power grid by the center of hub AC bus control requirements, and also conforms to the principle of power grid control hierarchical control. By using the method the control partition result is more adaptable and the influence of UHV-DC transmission power of the partition is considered as well. The rationality of the proposed method is verified by the simulation results of IEEE39 node system.

Authors

Institutions

Publication Details

Published
2024-11-22
DOI
https://doi.org/10.1109/ifeea64237.2024.10878526
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltage Control Partitioning Method Based on Weighted Fast-Newman for Ultra High Voltage Direct Current Power Grid

Lei Du, Tianhua Chen, Dawei Xu, Jianhua Chen
Power Systems and Renewable Energy
article

Voltage Control Partitioning Method Based on Weighted Fast-Newman for Ultra High Voltage Direct Current Power Grid

Lei Du, Tianhua Chen, Dawei Xu, Jianhua Chen
article en

Abstract

With the infeed UHV-DC merges into the power grid, the division of voltage control partitioning is more challenging, which is an important step in the secondary voltage control of power system. In this paper, the infeed UHV-DC node is equivalent to a reactive power supply, the weighted Fast-Newman algorithm is used to merge the reactive power sources through the maximum distance difference degree. The proposed method makes load nodes be divided with voltage reactive sensitivity and the average power factor. Which not only reflects the power grid by the center of hub AC bus control requirements, and also conforms to the principle of power grid control hierarchical control. By using the method the control partition result is more adaptable and the influence of UHV-DC transmission power of the partition is considered as well. The rationality of the proposed method is verified by the simulation results of IEEE39 node system.

NARI Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 69%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.