Influence of joint deformation on the auxetic behaviour of 3D printed polypropylene structures

Auxetic structures studied in the literature are often based on relatively stiff, metallic materials and theories regarding their response to mechanical loading cannot be translated directly to polymeric materials. As "soft" auxetics increase in popularity for applications in tissue engineering further investigation into the joint behaviour and effect on their Poisson's ratio is required. 3D printed polypropylene auxetic mesh structures were produced to compare to the requirements for biological cell-stretching devices while investigating the deformation mechanics. The behaviour of the meshes was characterised with tensile force-strain curves and high-definition imaging and the effect of joint behaviour on the Poisson's ratio was evaluated. Isolated unit cell samples of the re-entrant mesh were produced to characterise the in- and out-of-plane behaviour for geometries comprising re-entrant strut angles of 30, 45, and 60° to the tensile straining direction. Force-strain curves with three distinct phases were observed, with linear, plateau, and terminal regions characteristic of re-entrant honeycomb structures. A constant negative Poisson's ratio was measured up to a critical transition strain, at which point it is theorised that the onset of buckling triggers bending-dominated deformation to occur, out-of-plane. The production of full-scale mesh samples with the same 30, 45, and 60° geometry resulted in consistent values for critical transition strain and Poisson's ratios. An auxetic region of strain was defined, where the force is linear and a homogeneous negative Poisson's ratio can be maintained. This region represents the limit within which a biological cell-stretching device could operate successfully for the current mesh design.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2025-02-18
DOI
https://doi.org/10.1016/j.jmbbm.2025.106960
Citations
2
Primary Topic
Cellular and Composite Structures
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of joint deformation on the auxetic behaviour of 3D printed polypropylene structures

Jennifer H. Shepherd, Ruth E. Cameron, Serena M. Best
2 citations
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Cellular and Composite Structures
1.43
article

Influence of joint deformation on the auxetic behaviour of 3D printed polypropylene structures

Jennifer H. Shepherd, Ruth E. Cameron, Serena M. Best
article en
2 citations

Abstract

Auxetic structures studied in the literature are often based on relatively stiff, metallic materials and theories regarding their response to mechanical loading cannot be translated directly to polymeric materials. As "soft" auxetics increase in popularity for applications in tissue engineering further investigation into the joint behaviour and effect on their Poisson's ratio is required. 3D printed polypropylene auxetic mesh structures were produced to compare to the requirements for biological cell-stretching devices while investigating the deformation mechanics. The behaviour of the meshes was characterised with tensile force-strain curves and high-definition imaging and the effect of joint behaviour on the Poisson's ratio was evaluated. Isolated unit cell samples of the re-entrant mesh were produced to characterise the in- and out-of-plane behaviour for geometries comprising re-entrant strut angles of 30, 45, and 60° to the tensile straining direction. Force-strain curves with three distinct phases were observed, with linear, plateau, and terminal regions characteristic of re-entrant honeycomb structures. A constant negative Poisson's ratio was measured up to a critical transition strain, at which point it is theorised that the onset of buckling triggers bending-dominated deformation to occur, out-of-plane. The production of full-scale mesh samples with the same 30, 45, and 60° geometry resulted in consistent values for critical transition strain and Poisson's ratios. An auxetic region of strain was defined, where the force is linear and a homogeneous negative Poisson's ratio can be maintained. This region represents the limit within which a biological cell-stretching device could operate successfully for the current mesh design.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 166
University of Cambridge (GB)
Wellcome - MRC Cambridge Stem Cell Institute, University of Cambridge
Openalex Percentile: Top 22%
Cellular and Composite Structures
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.