Generation mechanism and influencing factors of transient overvoltage on ultra high-voltage direct current transmission

The transient overvoltage caused by faults in ultra-high-voltage direct current (UHVDC) transmission lines and alternating current (AC) systems can adversely affect system safety and stability. This study theoretically analyzes the transient overvoltage generation mechanism caused by DC single-pole ground faults and typical fault conditions in two different cases by combining the DC line and AC system of the transmitting side. Considering the different generation mechanisms of the two transient overvoltages, the main factors affecting transient overvoltages were determined to be the DC line ground fault location, DC filter main capacitance, AC system short-circuit ratio, and DC transmission power. Finally, through a simulation of UHVDC transmission engineering, the relationship between various influencing factors and overvoltage was obtained, which can provide guidance in transmission engineering UHVDC design.

Authors

Institutions

Publication Details

Journal
Frontiers in Energy Research
Published
2025-02-18
DOI
https://doi.org/10.3389/fenrg.2025.1461365
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Generation mechanism and influencing factors of transient overvoltage on ultra high-voltage direct current transmission

Weiwei Yao, Jie Zhao, Yilin Liang, Yushu Li et al.
1 citations
Frontiers in Energy Research
HVDC Systems and Fault Protection
0.73
article

Generation mechanism and influencing factors of transient overvoltage on ultra high-voltage direct current transmission

Weiwei Yao, Jie Zhao, Yilin Liang, Yushu Li, Jing Chen, Jinqiu Dou, Ye Deng
article en
1 citations

Abstract

The transient overvoltage caused by faults in ultra-high-voltage direct current (UHVDC) transmission lines and alternating current (AC) systems can adversely affect system safety and stability. This study theoretically analyzes the transient overvoltage generation mechanism caused by DC single-pole ground faults and typical fault conditions in two different cases by combining the DC line and AC system of the transmitting side. Considering the different generation mechanisms of the two transient overvoltages, the main factors affecting transient overvoltages were determined to be the DC line ground fault location, DC filter main capacitance, AC system short-circuit ratio, and DC transmission power. Finally, through a simulation of UHVDC transmission engineering, the relationship between various influencing factors and overvoltage was obtained, which can provide guidance in transmission engineering UHVDC design.

Frontiers in Energy ResearchVol. 13
China Three Gorges Corporation (China) (CN), Wuhan University of Technology (CN), Beijing Solar Energy Research Institute (CN), Wuhan University of Science and Technology (CN)
Openalex Percentile: Top 31%
HVDC Systems and Fault Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Generation mechanism and influencing factors of transient overvoltage on ultra high-voltage direct current transmission — Weiwei Yao, Jie Zhao, et al. · Frontiers in Energy Research (2025) | TGRS Research Map | TGRS