Microstructure and corrosion behavior of Ti–10Mo–6Zr–4Sn–3 Nb (Ti-B12) alloys as biomedical material in lactic acid-containing Hank's solution

Due to the growing interest in Ti and its alloys in the biomedical field, Ti–10Mo–6Zr–4Sn–3 Nb (Ti-B12) alloys have promising potential for orthopedic applications. However, although much work is related to the microstructures and mechanical properties of Ti-B12 alloys, their corrosion behavior, especially in the solution containing lactic acid, is still unclear. This work investigated the microstructures and electrochemical corrosion behavior of Ti-B12 alloys in Hank's solution with varying lactic acid concentrations. As-cast, deformed, and annealed Ti-B12 alloys were used as the samples. The results show that lactic acid plays a detrimental role in the corrosion resistance of the alloys. When the lactic acid concentration of Hank's solution is 0.075 wt% (pH = 3), the Ti-B12 alloys exhibit the highest corrosion current densities of 0.055 μA·cm −2 , 0.078 μA·cm −2 , and 0.098 μA·cm −2 , for the annealed, as-cast and deformed samples, respectively. Correspondingly, in such a situation, the impedances of the passive films formed after open circuit potential are 1.46 MΩ·cm 2 , 1.28 MΩ·cm 2, and 0.95 MΩ·cm 2 , which is about two-thirds of those in the Hank's solution with pH of 7. The lactic acid dissolves the outer layer of the passive film, resulting in an increased density of oxygen vacancies. The annealed sample exhibits refined grains in the microstructure, crucial for enhancing corrosion resistance. The as-cast samples display coarser grains. The grains are broken and elongated in the rolling direction in the deformed sample, leading to inferior performance in corrosive environments. This research provides critical insights into the potential applications of Ti-B12 alloys in biomedical environments.

Authors

Institutions

Publication Details

Journal
International Journal of Electrochemical Science
Published
2025-02-18
DOI
https://doi.org/10.1016/j.ijoes.2025.100974
Citations
9
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
4.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microstructure and corrosion behavior of Ti–10Mo–6Zr–4Sn–3 Nb (Ti-B12) alloys as biomedical material in lactic acid-containing Hank's solution

X. L. Wen, Shuai Hao, Yixuan He, Liang‐Yu Chen et al.
9 citations
International Journal of Electrochemical Science
Titanium Alloys Microstructure and Properties
4.66
article

Microstructure and corrosion behavior of Ti–10Mo–6Zr–4Sn–3 Nb (Ti-B12) alloys as biomedical material in lactic acid-containing Hank's solution

X. L. Wen, Shuai Hao, Yixuan He, Liang‐Yu Chen, Shangwen Liu, Jun Cheng
article en
9 citations

Abstract

Due to the growing interest in Ti and its alloys in the biomedical field, Ti–10Mo–6Zr–4Sn–3 Nb (Ti-B12) alloys have promising potential for orthopedic applications. However, although much work is related to the microstructures and mechanical properties of Ti-B12 alloys, their corrosion behavior, especially in the solution containing lactic acid, is still unclear. This work investigated the microstructures and electrochemical corrosion behavior of Ti-B12 alloys in Hank's solution with varying lactic acid concentrations. As-cast, deformed, and annealed Ti-B12 alloys were used as the samples. The results show that lactic acid plays a detrimental role in the corrosion resistance of the alloys. When the lactic acid concentration of Hank's solution is 0.075 wt% (pH = 3), the Ti-B12 alloys exhibit the highest corrosion current densities of 0.055 μA·cm −2 , 0.078 μA·cm −2 , and 0.098 μA·cm −2 , for the annealed, as-cast and deformed samples, respectively. Correspondingly, in such a situation, the impedances of the passive films formed after open circuit potential are 1.46 MΩ·cm 2 , 1.28 MΩ·cm 2, and 0.95 MΩ·cm 2 , which is about two-thirds of those in the Hank's solution with pH of 7. The lactic acid dissolves the outer layer of the passive film, resulting in an increased density of oxygen vacancies. The annealed sample exhibits refined grains in the microstructure, crucial for enhancing corrosion resistance. The as-cast samples display coarser grains. The grains are broken and elongated in the rolling direction in the deformed sample, leading to inferior performance in corrosive environments. This research provides critical insights into the potential applications of Ti-B12 alloys in biomedical environments.

International Journal of Electrochemical ScienceVol. 20(4)
Jiangsu University (CN), Northwestern Polytechnical University (CN), Jiangsu University of Science and Technology (CN), Northwest Institute For Non-Ferrous Metal Research (CN), Affiliated Hospital of Jiangsu University (CN)
National Natural Science Foundation of China, State Key Laboratory of Solidification Processing
Openalex Percentile: Top 5%
Titanium Alloys Microstructure and Properties
4.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.