ANTI-ADHESIVE MEMBRANES FOR CARDIOVASCULAR SURGERY - EFFICACY EVALUATION IN A LARGE ANIMALS STUDY

Highlights Formation of adhesions after chest surgery remains an unresolved issue. The use of biodegradable anti-adhesion membranes with anti-inflammatory activity can reduce the risk of adhesion. Preclinical assessment of the developed membranes in a large laboratory animal model is a mandatory step in the development of a medical device. Aim. To conduct a preclinical evaluation of the effectiveness of an anti-adhesive biodegradable membrane with anti-inflammatory activity in a large laboratory animal model (sheep). Methods . A composition of biodegradable polymers was used to manufacture the membranes: polylactide-co-glycolide copolymer (50:50) Mm 20–30 kDa and polylactide-co-glycolide (85:15). The polymers were dissolved in 1,1,1,3,3,3-hexafluoroisopropanol. To impart anti-inflammatory properties to the membrane, dexamethasone (DM) was added to the membrane composition at a final concentration of 1 mg DM/1 ml of polymer solution. The membranes were manufactured by electrospinning. The anti-adhesion efficiency of the membranes was assessed on an animal model (sheep) during implantation into the chest cavity. Results. In the control group of animals, a massive adhesive process was noted. In the experimental group, six animals (66.6%) had no adhesions at all, two animals (22.2%) had weak adhesion of the lung and pericardium in the area of ​​membrane fixation with suture material, and one animal (11.1%) had moderate adhesion of the pericardium to the surface of the chest cavity. Conclusion. The developed biodegradable membranes have demonstrated satisfactory anti-adhesive activity (88.8%). The implantation experience showed that it is better to use a membrane 30% larger in size than necessary to properly close the wound.

Authors

Institutions

Publication Details

Journal
Complex Issues of Cardiovascular Diseases
Published
2024-12-28
DOI
https://doi.org/10.17802/2306-1278-2024-13-4s-107-115
Primary Topic
Intestinal and Peritoneal Adhesions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANTI-ADHESIVE MEMBRANES FOR CARDIOVASCULAR SURGERY - EFFICACY EVALUATION IN A LARGE ANIMALS STUDY

Yu. А. Kudryavtseva, А. Н. Стасев, Anastasia Kanonykina, Egor S. Sardin
Complex Issues of Cardiovascular Diseases
Intestinal and Peritoneal Adhesions
article

ANTI-ADHESIVE MEMBRANES FOR CARDIOVASCULAR SURGERY - EFFICACY EVALUATION IN A LARGE ANIMALS STUDY

Yu. А. Kudryavtseva, А. Н. Стасев, Anastasia Kanonykina, Egor S. Sardin
article en

Abstract

Highlights Formation of adhesions after chest surgery remains an unresolved issue. The use of biodegradable anti-adhesion membranes with anti-inflammatory activity can reduce the risk of adhesion. Preclinical assessment of the developed membranes in a large laboratory animal model is a mandatory step in the development of a medical device. Aim. To conduct a preclinical evaluation of the effectiveness of an anti-adhesive biodegradable membrane with anti-inflammatory activity in a large laboratory animal model (sheep). Methods . A composition of biodegradable polymers was used to manufacture the membranes: polylactide-co-glycolide copolymer (50:50) Mm 20–30 kDa and polylactide-co-glycolide (85:15). The polymers were dissolved in 1,1,1,3,3,3-hexafluoroisopropanol. To impart anti-inflammatory properties to the membrane, dexamethasone (DM) was added to the membrane composition at a final concentration of 1 mg DM/1 ml of polymer solution. The membranes were manufactured by electrospinning. The anti-adhesion efficiency of the membranes was assessed on an animal model (sheep) during implantation into the chest cavity. Results. In the control group of animals, a massive adhesive process was noted. In the experimental group, six animals (66.6%) had no adhesions at all, two animals (22.2%) had weak adhesion of the lung and pericardium in the area of ​​membrane fixation with suture material, and one animal (11.1%) had moderate adhesion of the pericardium to the surface of the chest cavity. Conclusion. The developed biodegradable membranes have demonstrated satisfactory anti-adhesive activity (88.8%). The implantation experience showed that it is better to use a membrane 30% larger in size than necessary to properly close the wound.

Complex Issues of Cardiovascular DiseasesVol. 13(4S)
Kemerovo State University (RU)
Openalex Percentile: Top 53%
Intestinal and Peritoneal Adhesions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.