Performance of High Rise Structure with Lead Rubber Base as an Isolation System

A weak story, often referred to as a soft story, is one that has insufficient ductility to withstand the forces placed on the building by an earthquake. Buildings with soft stories typically have a story with a lot of open space. Since soft stories are traditionally associated with retail establishments and parking garages, they are frequently located on the lower stories of a building. As a result, when they collapse, they have the potential to bring the entire structure down, resulting in severe structural damage that may render the building completely unusable. However, there have only been a few studies on the impact of soft storeys at various levels in tall structures. This study will therefore investigate the impact of soft storey level variation in 45 storey building with and without LRB isolated structures.

Authors

Publication Details

Journal
International Journal for Research in Applied Science and Engineering Technology
Published
2025-02-18
DOI
https://doi.org/10.22214/ijraset.2025.66984
Primary Topic
Earthquake and Tsunami Effects
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of High Rise Structure with Lead Rubber Base as an Isolation System

Shaikh Qasim Qamar Sabiha
International Journal for Research in Applied Science and Engineering Technology
Earthquake and Tsunami Effects
article

Performance of High Rise Structure with Lead Rubber Base as an Isolation System

Shaikh Qasim Qamar Sabiha
article en

Abstract

A weak story, often referred to as a soft story, is one that has insufficient ductility to withstand the forces placed on the building by an earthquake. Buildings with soft stories typically have a story with a lot of open space. Since soft stories are traditionally associated with retail establishments and parking garages, they are frequently located on the lower stories of a building. As a result, when they collapse, they have the potential to bring the entire structure down, resulting in severe structural damage that may render the building completely unusable. However, there have only been a few studies on the impact of soft storeys at various levels in tall structures. This study will therefore investigate the impact of soft storey level variation in 45 storey building with and without LRB isolated structures.

International Journal for Research in Applied Science and Engineering TechnologyVol. 13(2)
Openalex Percentile: Top 97%
Earthquake and Tsunami Effects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.