Evaluation of In-Situ Low-Cost Sensor Network in a Tropical Valley, Colombia

The increase in yearly particulate matter concentrations has been a constant issue since 2017 in the Aburrá Valley, located in Antioquia, Colombia. Although local certified air quality monitors provide high accuracy, they are limited in spatial coverage, limiting chemical transport and pollution dynamic studies in this mountainous environment. In this work, a local, Low-Cost Sensor network is proposed as an alternative and has been installed around the valley in representative locations and heights. To calibrate PM<sub>2.5</sub> and O<sub>3</sub> sensors used by the network, temporal delays were analyzed with Dynamic Time Warping and the linear scale was corrected with a Single Linear Regression model. As a result, the correlation coefficient R<sup>2</sup> of the sensor reached values of 0.8 and 0.9 after calibration. For all network stations, rescaled data agrees with official historical reports on the behavior of pollutant concentrations and meteorological variables. The ability to compare the network results with certified data confirms the success of the calibration/validation method employed and contributes to the growing field of low-cost air quality sensors in Latin America.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-02-18
DOI
https://doi.org/10.3390/s25041236
Citations
7
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
5.59

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of In-Situ Low-Cost Sensor Network in a Tropical Valley, Colombia

Elena Montilla-Rosero, L. González
7 citations
Sensors
Air Quality Monitoring and Forecasting
5.59
article

Evaluation of In-Situ Low-Cost Sensor Network in a Tropical Valley, Colombia

Elena Montilla-Rosero, L. González
article en
7 citations

Abstract

The increase in yearly particulate matter concentrations has been a constant issue since 2017 in the Aburrá Valley, located in Antioquia, Colombia. Although local certified air quality monitors provide high accuracy, they are limited in spatial coverage, limiting chemical transport and pollution dynamic studies in this mountainous environment. In this work, a local, Low-Cost Sensor network is proposed as an alternative and has been installed around the valley in representative locations and heights. To calibrate PM<sub>2.5</sub> and O<sub>3</sub> sensors used by the network, temporal delays were analyzed with Dynamic Time Warping and the linear scale was corrected with a Single Linear Regression model. As a result, the correlation coefficient R<sup>2</sup> of the sensor reached values of 0.8 and 0.9 after calibration. For all network stations, rescaled data agrees with official historical reports on the behavior of pollutant concentrations and meteorological variables. The ability to compare the network results with certified data confirms the success of the calibration/validation method employed and contributes to the growing field of low-cost air quality sensors in Latin America.

SensorsVol. 25(4)
Universidad EAFIT (CO)
Universidad EAFIT
Openalex Percentile: Top 5%
Air Quality Monitoring and Forecasting
5.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.