Calibration of a Low-Cost Particulate Matter Sensor Using the Decay Method

Abstract Air pollution, particularly particulate matter (PM), poses significant health risks and environmental challenges. Real-time air quality monitoring is crucial for effective management and mitigation strategies, especially in personal exposure contexts. Wearable devices, commonly utilizing low-cost optical PM sensors, offer a promising solution. However, these low-cost sensors often require recalibration to ensure accuracy and reliability. This study focuses on calibrating the SPS30 particulate matter sensor, a popular optical sensor, to improve its performance for wearable applications. The calibration process was conducted using the decay method in an aerosol chamber, aligning the SPS30’s readings with those of a reference sensor (HT-9600). The results demonstrated an excellent correlation between the SPS30 and the reference sensor for both PM2.5 and PM10 measurements. This study confirms that proper calibration can enhance the SPS30’s accuracy, making it a reliable tool for real-time, personal air quality monitoring, which is essential for public health and environmental management.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-02-01
DOI
https://doi.org/10.1088/1742-6596/2942/1/012042
Citations
3
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
2.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of a Low-Cost Particulate Matter Sensor Using the Decay Method

Rahmat Awaludin Salam, Casmika Saputra, Muhammad Nur Faqiih, Asthari Fachsya Thalia et al.
3 citations
Journal of Physics Conference Series
Air Quality Monitoring and Forecasting
2.40
article

Calibration of a Low-Cost Particulate Matter Sensor Using the Decay Method

Rahmat Awaludin Salam, Casmika Saputra, Muhammad Nur Faqiih, Asthari Fachsya Thalia, Imel Aprilyana Safari
article en
3 citations

Abstract

Abstract Air pollution, particularly particulate matter (PM), poses significant health risks and environmental challenges. Real-time air quality monitoring is crucial for effective management and mitigation strategies, especially in personal exposure contexts. Wearable devices, commonly utilizing low-cost optical PM sensors, offer a promising solution. However, these low-cost sensors often require recalibration to ensure accuracy and reliability. This study focuses on calibrating the SPS30 particulate matter sensor, a popular optical sensor, to improve its performance for wearable applications. The calibration process was conducted using the decay method in an aerosol chamber, aligning the SPS30’s readings with those of a reference sensor (HT-9600). The results demonstrated an excellent correlation between the SPS30 and the reference sensor for both PM2.5 and PM10 measurements. This study confirms that proper calibration can enhance the SPS30’s accuracy, making it a reliable tool for real-time, personal air quality monitoring, which is essential for public health and environmental management.

Journal of Physics Conference SeriesVol. 2942(1)
Telkom University (ID)
Openalex Percentile: Top 14%
Air Quality Monitoring and Forecasting
2.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.