Experimental study and performance analysis of direct coupled solar vapor compression refrigeration system

Abstract The solar powered vapor compression refrigeration system with or without load was experimentally studied and analyzed. The results showed that the refrigeration system can work normally with a DC compressor working time of 8 hours, the refrigeration system can reach a temperature of -6.9°C and 2.9°C respectively at no-load and with-load conditions. The COP obtained was 3.094 and 2.786 respectively at no-load and with-load conditions. The average efficiency of the photovoltaic solar panel is known to be 10.94% and 10.69% respectively at no-load and with-load conditions. The results of the sizing calculation for the refrigeration system without a cooling load required a 150Wp photovoltaic solar panel, a 12V 42Ah battery and a 20A solar charge controller. While when the refrigeration system works with a load, a 200Wp photovoltaic solar panel, a 12V 50Ah battery and a 20A solar charge controller are required.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-02-01
DOI
https://doi.org/10.1088/1742-6596/2942/1/012028
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study and performance analysis of direct coupled solar vapor compression refrigeration system

Himsar Ambarita, H V Sihombing, Tulus Burhanuddin Sitorus, Rinaldo H. Malau et al.
Journal of Physics Conference Series
Refrigeration and Air Conditioning Technologies
article

Experimental study and performance analysis of direct coupled solar vapor compression refrigeration system

Himsar Ambarita, H V Sihombing, Tulus Burhanuddin Sitorus, Rinaldo H. Malau, Rony Setiawan
article en

Abstract

Abstract The solar powered vapor compression refrigeration system with or without load was experimentally studied and analyzed. The results showed that the refrigeration system can work normally with a DC compressor working time of 8 hours, the refrigeration system can reach a temperature of -6.9°C and 2.9°C respectively at no-load and with-load conditions. The COP obtained was 3.094 and 2.786 respectively at no-load and with-load conditions. The average efficiency of the photovoltaic solar panel is known to be 10.94% and 10.69% respectively at no-load and with-load conditions. The results of the sizing calculation for the refrigeration system without a cooling load required a 150Wp photovoltaic solar panel, a 12V 42Ah battery and a 20A solar charge controller. While when the refrigeration system works with a load, a 200Wp photovoltaic solar panel, a 12V 50Ah battery and a 20A solar charge controller are required.

Journal of Physics Conference SeriesVol. 2942(1)
Universitas Sumatera Utara (ID)
Openalex Percentile: Top 97%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.