3D-Printed Brace Utilization for an Isolated Fibular Head Fracture: A Case Report

Isolated fibular head fractures are rare and often result from direct trauma to the lateral knee or varus stress. These fractures, accounting for a small percentage of fibular fractures, can be challenging to diagnose on initial imaging. We present a case of a 65-year-old man who sustained a blow to the right fibular head from a cow's kick. Initial X-rays were inconclusive, but an MRI revealed an impacted fibular head fracture. The patient was managed conservatively with a 3D-printed brace, a walking boot, and crutches for mobility support. The brace, made of carbon fiber nylon with a thickness of 4 mm, was secured using an elastic bandage and rubber adhesive. It provided lateral stability and pressure to the tibial head, improving the patient's perceived stability while walking. The patient recovered fully without complications. Unlike fractures of the distal fibula, which often require surgical intervention, fibular head fractures rarely need surgery and can be managed effectively with conservative measures. This case highlights the value of advanced imaging and customized 3D-printed bracing in managing isolated fibular head fractures.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-02-18
DOI
https://doi.org/10.7759/cureus.79220
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-Printed Brace Utilization for an Isolated Fibular Head Fracture: A Case Report

Michael D. Goodlett, Kenny V. Brock, Vincent Lee, Ji Hyun Lee et al.
Cureus
Orthopedic Surgery and Rehabilitation
article

3D-Printed Brace Utilization for an Isolated Fibular Head Fracture: A Case Report

Michael D. Goodlett, Kenny V. Brock, Vincent Lee, Ji Hyun Lee, Rana Haggag
article en

Abstract

Isolated fibular head fractures are rare and often result from direct trauma to the lateral knee or varus stress. These fractures, accounting for a small percentage of fibular fractures, can be challenging to diagnose on initial imaging. We present a case of a 65-year-old man who sustained a blow to the right fibular head from a cow's kick. Initial X-rays were inconclusive, but an MRI revealed an impacted fibular head fracture. The patient was managed conservatively with a 3D-printed brace, a walking boot, and crutches for mobility support. The brace, made of carbon fiber nylon with a thickness of 4 mm, was secured using an elastic bandage and rubber adhesive. It provided lateral stability and pressure to the tibial head, improving the patient's perceived stability while walking. The patient recovered fully without complications. Unlike fractures of the distal fibula, which often require surgical intervention, fibular head fractures rarely need surgery and can be managed effectively with conservative measures. This case highlights the value of advanced imaging and customized 3D-printed bracing in managing isolated fibular head fractures.

CureusVol. 17(2)
Auburn University (US), Edward Via College of Osteopathic Medicine (US)
Openalex Percentile: Top 95%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

3D-Printed Brace Utilization for an Isolated Fibular Head Fracture: A Case Report — Michael D. Goodlett, Kenny V. Brock, et al. · Cureus (2025) | TGRS Research Map | TGRS