On-site trihalomethanes extraction from water using 3D printing solid phase extraction device and analysis by GC-ECD

• 3D-printed SPE-coated device enables on-site extraction of 4 trihalomethanes for GC-ECD. • The 3D printed device-GC-ECD system achieves very satisfactory analytical performance. • Miniaturized, easy fabrication and practical method. • Good performance for the analysis of wastewater effluent and tap water samples. A 3D-printed device coated with SDB-1 resin was developed for on-site extraction and preconcentration of trihalomethanes (THMs) and subsequent determination by gas chromatography (GC) with an electron capture detector (ECD). This device was fabricated by stereolithography and covered with a commercial SPE resin using the stick & cure immobilization technique. Various parameters that affect extraction efficiency and preconcentration (resin type, conditioning mode, extraction modality, extraction time, and eluent volume) were optimized using four THMs (Chloroform, TCM; Bromodichloromethane, BDCM; Dibromochloromethane, DBCM; and Tribromomethane, TBM) and an internal standard (1,2-dibromopropane). Under the optimized conditions, good linearity for THMs studied were obtained in a range of 0.25–100 µg L −1 with r ≥ 0.998 and limits of detection between 0.02–0.05 µg L −1 . The precision expressed as relative standard deviation (%RSD, n = 3), showed intraday and interday ranges of 1.8–4.2 % and 3.3–9.4 %, respectively, demonstrating a good precision of the proposed methodology. The proposed method was successfully applied to the simultaneous analysis of four THMs in wastewater effluent and tap water samples, revealing total concentrations of 34.1 and 78.1 µg L −1 , respectively. This user-friendly and miniaturized device features a simple extraction procedure (up to 24-fold enrichment), with excellent sensitivity and precision, which is very useful and practical for the simultaneous analysis of volatile compounds. Additionally, three greenness evaluation methodologies (AGREE, AGREEprep, and GAPI) and a practicality tool (BAGI) were employed to assess the environmental friendliness and applicability of the proposed method, demonstrating its superior performance compared to previously reported GC methods in the literature.

Authors

Institutions

Publication Details

Journal
Talanta Open
Published
2025-02-18
DOI
https://doi.org/10.1016/j.talo.2025.100420
Citations
2
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
1.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-site trihalomethanes extraction from water using 3D printing solid phase extraction device and analysis by GC-ECD

Diego Barzallo, Edwin Palacio, Héctor Berdugo
2 citations
Talanta Open
Analytical chemistry methods development
1.50
article

On-site trihalomethanes extraction from water using 3D printing solid phase extraction device and analysis by GC-ECD

Diego Barzallo, Edwin Palacio, Héctor Berdugo
article en
2 citations

Abstract

• 3D-printed SPE-coated device enables on-site extraction of 4 trihalomethanes for GC-ECD. • The 3D printed device-GC-ECD system achieves very satisfactory analytical performance. • Miniaturized, easy fabrication and practical method. • Good performance for the analysis of wastewater effluent and tap water samples. A 3D-printed device coated with SDB-1 resin was developed for on-site extraction and preconcentration of trihalomethanes (THMs) and subsequent determination by gas chromatography (GC) with an electron capture detector (ECD). This device was fabricated by stereolithography and covered with a commercial SPE resin using the stick & cure immobilization technique. Various parameters that affect extraction efficiency and preconcentration (resin type, conditioning mode, extraction modality, extraction time, and eluent volume) were optimized using four THMs (Chloroform, TCM; Bromodichloromethane, BDCM; Dibromochloromethane, DBCM; and Tribromomethane, TBM) and an internal standard (1,2-dibromopropane). Under the optimized conditions, good linearity for THMs studied were obtained in a range of 0.25–100 µg L −1 with r ≥ 0.998 and limits of detection between 0.02–0.05 µg L −1 . The precision expressed as relative standard deviation (%RSD, n = 3), showed intraday and interday ranges of 1.8–4.2 % and 3.3–9.4 %, respectively, demonstrating a good precision of the proposed methodology. The proposed method was successfully applied to the simultaneous analysis of four THMs in wastewater effluent and tap water samples, revealing total concentrations of 34.1 and 78.1 µg L −1 , respectively. This user-friendly and miniaturized device features a simple extraction procedure (up to 24-fold enrichment), with excellent sensitivity and precision, which is very useful and practical for the simultaneous analysis of volatile compounds. Additionally, three greenness evaluation methodologies (AGREE, AGREEprep, and GAPI) and a practicality tool (BAGI) were employed to assess the environmental friendliness and applicability of the proposed method, demonstrating its superior performance compared to previously reported GC methods in the literature.

Talanta OpenVol. 11
Universidad Estatal de Milagro (EC), Universitat de les Illes Balears (ES)
Clean water and sanitation
Openalex Percentile: Top 22%
Analytical chemistry methods development
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.