Surface Contamination Detection of Composite Insulators Based on Leakage Current

As an important part of the transmission line, the contamination accumulated on the surface of the insulator will cause pollution flashover accidents under the action of external conditions. [1], [2] Therefore, it is very important to predict the pollution state of the operating insulator in time to avoid the occurrence of flashover accidents. Firstly, the artificial contamination test was carried out on the ceramic plate brushed with RTV hydrophobic coating to obtain the leakage current data under different salt densities. Secondly, the characteristic quantities of leakage current are extracted: effective value, maximum value and standard deviation, which are used as input variables of BP neural network. Finally, the network model for judging the contamination state of insulators is tested. The results show that the three characteristic quantities can provide effective information for the detection of insulator pollution degree, and the network model for judging the pollution state of insulators can effectively predict the pollution state of insulators.

Authors

Institutions

Publication Details

Published
2024-11-22
DOI
https://doi.org/10.1109/ifeea64237.2024.10878605
Citations
2
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface Contamination Detection of Composite Insulators Based on Leakage Current

Wenzhuo Wang, He Jun, Tao Shi, Jun Zhu et al.
2 citations
Non-Destructive Testing Techniques
0.43
article

Surface Contamination Detection of Composite Insulators Based on Leakage Current

Wenzhuo Wang, He Jun, Tao Shi, Jun Zhu, Kang Yang
article en
2 citations

Abstract

As an important part of the transmission line, the contamination accumulated on the surface of the insulator will cause pollution flashover accidents under the action of external conditions. [1], [2] Therefore, it is very important to predict the pollution state of the operating insulator in time to avoid the occurrence of flashover accidents. Firstly, the artificial contamination test was carried out on the ceramic plate brushed with RTV hydrophobic coating to obtain the leakage current data under different salt densities. Secondly, the characteristic quantities of leakage current are extracted: effective value, maximum value and standard deviation, which are used as input variables of BP neural network. Finally, the network model for judging the contamination state of insulators is tested. The results show that the three characteristic quantities can provide effective information for the detection of insulator pollution degree, and the network model for judging the pollution state of insulators can effectively predict the pollution state of insulators.

Southwest Minzu University (CN)
Openalex Percentile: Top 40%
Non-Destructive Testing Techniques
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Surface Contamination Detection of Composite Insulators Based on Leakage Current — Wenzhuo Wang, He Jun, et al. · (2024) | TGRS Research Map | TGRS