Application Study of High Performance Graphene/Polyether Composites

The increased voltage level and power density of the power system result in higher currents and overheating at the electrical connection contactors, easily leading to line and equipment failures and damage. On this basis, we prepared a graphene/polyether composite, which can effectively reduce contact resistance. To verify the performance of our products, comparison experiments of graphene/polyether composite and several common products in the power system were carried out. The results showed that the volumetric resistivity of the graphene/polyether composite was only 1.6x10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sup>Ω • m, and the dropping point was higher than 330°C (The standard is 200°C). Besides, the stabilization factor of contact resistance after the salt spray test was only 0.81 (The standard is 1.5), and the stability coefficient of contact resistance after the temperature alternating test was only 1.06 (The standard is 1.5). Therefore, graphene/polyether composite's electrical conductivity and antiaging properties are significantly better than those of traditional electrical joint compounds, and it has broad application prospects.

Authors

Institutions

Publication Details

Published
2024-11-22
DOI
https://doi.org/10.1109/ifeea64237.2024.10878676
Primary Topic
Fiber-reinforced polymer composites
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application Study of High Performance Graphene/Polyether Composites

Fangcheng Qiu, Xinyuan Lu, Yunhua He, Yufeng Song et al.
Fiber-reinforced polymer composites
article

Application Study of High Performance Graphene/Polyether Composites

Fangcheng Qiu, Xinyuan Lu, Yunhua He, Yufeng Song, Faping Hu
article en

Abstract

The increased voltage level and power density of the power system result in higher currents and overheating at the electrical connection contactors, easily leading to line and equipment failures and damage. On this basis, we prepared a graphene/polyether composite, which can effectively reduce contact resistance. To verify the performance of our products, comparison experiments of graphene/polyether composite and several common products in the power system were carried out. The results showed that the volumetric resistivity of the graphene/polyether composite was only 1.6x10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sup>Ω • m, and the dropping point was higher than 330°C (The standard is 200°C). Besides, the stabilization factor of contact resistance after the salt spray test was only 0.81 (The standard is 1.5), and the stability coefficient of contact resistance after the temperature alternating test was only 1.06 (The standard is 1.5). Therefore, graphene/polyether composite's electrical conductivity and antiaging properties are significantly better than those of traditional electrical joint compounds, and it has broad application prospects.

Beijing Jiaotong University (CN), China Southern Power Grid (China) (CN)
Openalex Percentile: Top 72%
Fiber-reinforced polymer composites
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.