Synthesis of Water-Resistant Polyurethane Composite for Underwater Transducers Encapsulation

The encapsulation of underwater transducers poses a significant challenge due to the need for water resistance and acoustic matching properties. This study presents a comprehensive investigation on the synthesis of water-resistant polyurethane composites and their performance as encapsulation materials for underwater transducers. Four different samples were synthesized for study: polyurethane (PU), PU-AER200 (PU with 4% hydrophilic filler), PU-R972 (PU with 4% hydrophobic filler), and PU-Kaolin (PU with 4% Nanoclay). The water absorption measurements revealed that pure PU exhibited 2% water absorption, while PU-AER200, PU-R972, and PU-Kaolin demonstrated 2.7%, 0.5%, and 0.9% water absorption, respectively. Additionally, the moisture transmissibility values were obtained, with PU-AER200 exhibiting the highest moisture transmission value of 202 g/m2/24 hr, followed by PU (170 g/m2/24 hr), PU-Kaolin (130 g/m2/24 hr) and PU-R972 (90 g/m2/24 hr). DC volume resistivity in the dry state was measured, resulting in 3 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{T}\Omega \mathbf{m}$</tex> for PU, 2 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{T}\Omega \mathbf{m}$</tex> for PU-AER200, 7 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{T}\Omega \mathbf{m}$</tex> for PU-R972, and 6 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{T}\Omega \mathbf{m}$</tex> for PU-Kaolin. After water absorption, PU-R972 shows lowest drop in resistivity. The acoustic impedance of the materials was evaluated to assess their acoustic matching capabilities with water, a crucial requirement for transducers. All samples showed impedance values close to that of water (1.48 MRay1), with PU (1.56 MRayl), PU-AER200 (1.52 MRayl), PU-R972 (1.50 MRayl), and PU-Kaolin (1.50 MRayl). PU-R972 shows closest matching impedance values with water. To validate the practical application of the synthesized samples, Acoustic Transducers were molded with each material, submerged in a water tank, and tested for transducer voltage response (TVR) and free-field voltage response (FFVR). The results indicated that PU-R972 achieved the highest TVR value of 148.9 dB at a frequency of 7.4 kHz, while PU-AER200 exhibited the lowest TVR of 140.1 dB. Similarly, for FFVR at 8 kHz, PU-R972 yielded the highest value of -166.8 dB, and PU-AER200 displayed the lowest value of -170.8 dB.

Authors

Publication Details

Published
2024-08-20
DOI
https://doi.org/10.1109/ibcast61650.2024.10876930
Primary Topic
Polymer composites and self-healing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis of Water-Resistant Polyurethane Composite for Underwater Transducers Encapsulation

Adnan Qaseem, Ammar Hasan Asghar, Shahid Ali, Saqib Nasim
Polymer composites and self-healing
article

Synthesis of Water-Resistant Polyurethane Composite for Underwater Transducers Encapsulation

Adnan Qaseem, Ammar Hasan Asghar, Shahid Ali, Saqib Nasim
article en

Abstract

The encapsulation of underwater transducers poses a significant challenge due to the need for water resistance and acoustic matching properties. This study presents a comprehensive investigation on the synthesis of water-resistant polyurethane composites and their performance as encapsulation materials for underwater transducers. Four different samples were synthesized for study: polyurethane (PU), PU-AER200 (PU with 4% hydrophilic filler), PU-R972 (PU with 4% hydrophobic filler), and PU-Kaolin (PU with 4% Nanoclay). The water absorption measurements revealed that pure PU exhibited 2% water absorption, while PU-AER200, PU-R972, and PU-Kaolin demonstrated 2.7%, 0.5%, and 0.9% water absorption, respectively. Additionally, the moisture transmissibility values were obtained, with PU-AER200 exhibiting the highest moisture transmission value of 202 g/m2/24 hr, followed by PU (170 g/m2/24 hr), PU-Kaolin (130 g/m2/24 hr) and PU-R972 (90 g/m2/24 hr). DC volume resistivity in the dry state was measured, resulting in 3 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{T}\Omega \mathbf{m}$</tex> for PU, 2 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{T}\Omega \mathbf{m}$</tex> for PU-AER200, 7 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{T}\Omega \mathbf{m}$</tex> for PU-R972, and 6 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{T}\Omega \mathbf{m}$</tex> for PU-Kaolin. After water absorption, PU-R972 shows lowest drop in resistivity. The acoustic impedance of the materials was evaluated to assess their acoustic matching capabilities with water, a crucial requirement for transducers. All samples showed impedance values close to that of water (1.48 MRay1), with PU (1.56 MRayl), PU-AER200 (1.52 MRayl), PU-R972 (1.50 MRayl), and PU-Kaolin (1.50 MRayl). PU-R972 shows closest matching impedance values with water. To validate the practical application of the synthesized samples, Acoustic Transducers were molded with each material, submerged in a water tank, and tested for transducer voltage response (TVR) and free-field voltage response (FFVR). The results indicated that PU-R972 achieved the highest TVR value of 148.9 dB at a frequency of 7.4 kHz, while PU-AER200 exhibited the lowest TVR of 140.1 dB. Similarly, for FFVR at 8 kHz, PU-R972 yielded the highest value of -166.8 dB, and PU-AER200 displayed the lowest value of -170.8 dB.

Life below water
Openalex Percentile: Top 79%
Polymer composites and self-healing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.