Characterizing Recent PDMS Changes in Electrokinetic‐Based Microfluidic Devices’ Performance and Manufacturing for Cell Sorting Applications

Understanding cells from complex biological samples is vital to understanding cellular biology and medical applications. One evolving tool for cell sorting is the use of microfluidic devices to achieve higher precision and remove the need for labeling cell subpopulations. However, few microfluidic devices have been translated commercially beyond academic research often due to challenges in larger scale fabrication. Here, we initially investigated a compelling label-free microfluidic device with complex geometries to perform contactless dielectrophoresis (cDEP) for applications in enriching cell subpopulations in oncology, neurology, stem cells, and sample preparation. We began scaling the manufacturing of cDEP devices using Dow Sylgard 184, more commonly referred to as PDMS (polydimethylsiloxane). However, we began observing a new, dynamic bubble formation phenomenon which had significant impacts on device performance. Within just 5 min of exposure at typical experimental values, cell death was nearly 100%. Variables related to manufacturing, environment, equipment, personnel, raw materials sourcing, lithography methods and experimental conditions/parameters were systematically evaluated to find the root cause of the exacerbated bubble formation observed. Further, alternate polymers were sourced for manufacturing and experimental performance comparisons. All variables investigated failed to solve the significant decline in device performance and increase in cell death. Upon completing chemical analysis in this work, we conclude that the decline in device performance was a direct result of changes to the expected PDMS properties and composition. Despite these challenges, our robust quality control combined with experimental protocols to remove bubbles from the cDEP devices achieved consistent experimental performance including 2-3 h run times and >90% cell viability after sorting. These new PDMS behaviors will need to continue to be monitored and controlled to ensure consistency in experimentation, application and commercialization feasibility for a wide variety of microfluidic device designs and applications.

Authors

Institutions

Publication Details

Journal
Electrophoresis
Published
2025-02-18
DOI
https://doi.org/10.1002/elps.8113
Citations
3
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterizing Recent PDMS Changes in Electrokinetic‐Based Microfluidic Devices’ Performance and Manufacturing for Cell Sorting Applications

Rafael V. Davalos, Jeff Schultz, Steven A. Soper, Jaka Čemažar et al.
3 citations
Electrophoresis
Microfluidic and Bio-sensing Technologies
2.02
article

Characterizing Recent PDMS Changes in Electrokinetic‐Based Microfluidic Devices’ Performance and Manufacturing for Cell Sorting Applications

Rafael V. Davalos, Jeff Schultz, Steven A. Soper, Jaka Čemažar, Farhad Shiri, Sue Brown, Kimberly M. Brown, Dean E. Thomas, Alexandra R. Hyler, Nathan S. Swami, Josie L. Duncan, Kyle S. Kinskie
article en
3 citations

Abstract

Understanding cells from complex biological samples is vital to understanding cellular biology and medical applications. One evolving tool for cell sorting is the use of microfluidic devices to achieve higher precision and remove the need for labeling cell subpopulations. However, few microfluidic devices have been translated commercially beyond academic research often due to challenges in larger scale fabrication. Here, we initially investigated a compelling label-free microfluidic device with complex geometries to perform contactless dielectrophoresis (cDEP) for applications in enriching cell subpopulations in oncology, neurology, stem cells, and sample preparation. We began scaling the manufacturing of cDEP devices using Dow Sylgard 184, more commonly referred to as PDMS (polydimethylsiloxane). However, we began observing a new, dynamic bubble formation phenomenon which had significant impacts on device performance. Within just 5 min of exposure at typical experimental values, cell death was nearly 100%. Variables related to manufacturing, environment, equipment, personnel, raw materials sourcing, lithography methods and experimental conditions/parameters were systematically evaluated to find the root cause of the exacerbated bubble formation observed. Further, alternate polymers were sourced for manufacturing and experimental performance comparisons. All variables investigated failed to solve the significant decline in device performance and increase in cell death. Upon completing chemical analysis in this work, we conclude that the decline in device performance was a direct result of changes to the expected PDMS properties and composition. Despite these challenges, our robust quality control combined with experimental protocols to remove bubbles from the cDEP devices achieved consistent experimental performance including 2-3 h run times and >90% cell viability after sorting. These new PDMS behaviors will need to continue to be monitored and controlled to ensure consistency in experimentation, application and commercialization feasibility for a wide variety of microfluidic device designs and applications.

ElectrophoresisVol. 46(16)
The Wallace H. Coulter Department of Biomedical Engineering (US), Phasex (United States) (US), University of Virginia (US)
National Science Foundation, Norges Idrettshøgskole
Openalex Percentile: Top 16%
Microfluidic and Bio-sensing Technologies
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.