Verification of the Inactivation Effect of Near-UV LEDs using a Pulsed Lighting System on Staphylococcus aureus
The purpose of this study is to investigate the disinfection effect of Near-UV LED light, which is pulsed using PWM control, on Staphylococcus aureus. To evaluate the disinfection effect of Near-UV LED light, three types of Near-UV LEDs with wavelengths of 395 nm, 385 nm, and 365 nm were installed within a sealed space inside an incubator and energized with a forward current of 1000 mA and a forward voltage of 3.6 V, and the disinfection rate under each type of light was assessed. Additionally, the disinfection effect was evaluated when the same three types of Near-UV LEDs were pulsed with a 50% duty cycle. As a result, 100% disinfection was achieved with 365 nm Near-UV LED direct-current irradiation for 120 seconds, and a 93% disinfection rate was obtained with pulsed irradiation for 150 seconds.