Verification of the Inactivation Effect of Near-UV LEDs using a Pulsed Lighting System on Staphylococcus aureus

The purpose of this study is to investigate the disinfection effect of Near-UV LED light, which is pulsed using PWM control, on Staphylococcus aureus. To evaluate the disinfection effect of Near-UV LED light, three types of Near-UV LEDs with wavelengths of 395 nm, 385 nm, and 365 nm were installed within a sealed space inside an incubator and energized with a forward current of 1000 mA and a forward voltage of 3.6 V, and the disinfection rate under each type of light was assessed. Additionally, the disinfection effect was evaluated when the same three types of Near-UV LEDs were pulsed with a 50% duty cycle. As a result, 100% disinfection was achieved with 365 nm Near-UV LED direct-current irradiation for 120 seconds, and a 93% disinfection rate was obtained with pulsed irradiation for 150 seconds.

Authors

Institutions

Publication Details

Published
2024-11-12
DOI
https://doi.org/10.1109/ls2463127.2024.10881155
Primary Topic
bioluminescence and chemiluminescence research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification of the Inactivation Effect of Near-UV LEDs using a Pulsed Lighting System on Staphylococcus aureus

Hiroki Nomura, Jun Sawai, Akinori Zukeran, Shusaku Kihara et al.
bioluminescence and chemiluminescence research
article

Verification of the Inactivation Effect of Near-UV LEDs using a Pulsed Lighting System on Staphylococcus aureus

Hiroki Nomura, Jun Sawai, Akinori Zukeran, Shusaku Kihara, Takayuki Misu
article en

Abstract

The purpose of this study is to investigate the disinfection effect of Near-UV LED light, which is pulsed using PWM control, on Staphylococcus aureus. To evaluate the disinfection effect of Near-UV LED light, three types of Near-UV LEDs with wavelengths of 395 nm, 385 nm, and 365 nm were installed within a sealed space inside an incubator and energized with a forward current of 1000 mA and a forward voltage of 3.6 V, and the disinfection rate under each type of light was assessed. Additionally, the disinfection effect was evaluated when the same three types of Near-UV LEDs were pulsed with a 50% duty cycle. As a result, 100% disinfection was achieved with 365 nm Near-UV LED direct-current irradiation for 120 seconds, and a 93% disinfection rate was obtained with pulsed irradiation for 150 seconds.

Kanagawa Institute of Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 78%
bioluminescence and chemiluminescence research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Verification of the Inactivation Effect of Near-UV LEDs using a Pulsed Lighting System on Staphylococcus aureus — Hiroki Nomura, Jun Sawai, et al. · (2024) | TGRS Research Map | TGRS