Development of Respiration Measurement Methods Using Wearable Gyroscope and Acceleration Sensors

To diagnose respiratory diseases, it is essential to quantify the respiratory rate and respiratory movements.Moreover, the assessment of respiratory movements is a valuable tool for the evaluation of autonomic nervous system function, including the assessment of stress load.The present techniques for measuring respiration encompass the thermistor method, inductance method, and electrical impedance method.However, the thermistor and inductance methods present certain difficulties in terms of sensor attachment, and they place a significant burden on the subject.Furthermore, the electrical impedance method is susceptible to the effects of body movements and other factors.Conversely, considerable research is being conducted on the use of IoT in the development of wearable healthcare devices, which employ gyroscope and acceleration sensors.In this study, we attempted to measure respiratory movements by attaching a 6-axis sensor (comprising a 3-axis gyroscope sensor and a 3-axis acceleration sensor) to the chest.As a result, it was demonstrated that respiratory movements can be accurately measured even when the 6-axis sensor is attached to clothing.

Authors

Institutions

Publication Details

Journal
Sensors and Materials
Published
2025-02-18
DOI
https://doi.org/10.18494/sam5391
Primary Topic
Energy and Environmental Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Respiration Measurement Methods Using Wearable Gyroscope and Acceleration Sensors

Akira Ikarashi
Sensors and Materials
Energy and Environmental Systems
article

Development of Respiration Measurement Methods Using Wearable Gyroscope and Acceleration Sensors

Akira Ikarashi
article en

Abstract

To diagnose respiratory diseases, it is essential to quantify the respiratory rate and respiratory movements.Moreover, the assessment of respiratory movements is a valuable tool for the evaluation of autonomic nervous system function, including the assessment of stress load.The present techniques for measuring respiration encompass the thermistor method, inductance method, and electrical impedance method.However, the thermistor and inductance methods present certain difficulties in terms of sensor attachment, and they place a significant burden on the subject.Furthermore, the electrical impedance method is susceptible to the effects of body movements and other factors.Conversely, considerable research is being conducted on the use of IoT in the development of wearable healthcare devices, which employ gyroscope and acceleration sensors.In this study, we attempted to measure respiratory movements by attaching a 6-axis sensor (comprising a 3-axis gyroscope sensor and a 3-axis acceleration sensor) to the chest.As a result, it was demonstrated that respiratory movements can be accurately measured even when the 6-axis sensor is attached to clothing.

Sensors and MaterialsVol. 37(2)
Aino University (JP)
Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 97%
Energy and Environmental Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.