A model-based continuous commissioning method for an efficient integration of ground source heat pumps in the building ecosystem

This paper introduces a model-based continuous commissioning (MBCCx) methodology specifically designed for the identification of control-related performance gaps within heating, ventilation and air conditioning (HVAC) systems equipped with ground-source heat pumps (GSHPs). While conventional continuous commissioning (CCx) is effective in detecting energy performance gaps, MBCCx goes further by using a system model as a reference to pinpoint operational inefficiencies and control faults arising from subsystem integration. The core of the proposed methodology lies in a calibrated physics-based model that represents the system performance as intended during the design phase. A key advantage is its applicability early in a building’s operational phase, when data is limited, unlike data-driven methods that rely on extensive historical datasets. This enables the identification of energy-saving opportunities before the system reaches a stable operational state. To address the limitations of prior studies that often focus solely on individual GSHP component performance, this work pioneers the application of MBCCx to whole buildings equipped with GSHPs. The proposed approach employs a detailed 3D building model and component-level HVAC modeling to predict parameters such as room temperatures, heat pump power, and ground heat exchanger temperatures under normal conditions. Significant deviations between monitored values and model predictions serve as indicators of underperforming components or control sequence anomalies. The anomaly detection accuracy is then improved by merging HVAC system and GSHP performance indicators. The methodology is demonstrated through a case study of a recently retrofitted elementary school in Québec, Canada, equipped with five standing column wells as ground heat exchangers.

Authors

Publication Details

Journal
Energy and Buildings
Published
2025-02-18
DOI
https://doi.org/10.1016/j.enbuild.2025.115492
Citations
6
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
6.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A model-based continuous commissioning method for an efficient integration of ground source heat pumps in the building ecosystem

Philippe Pasquier, Michaël Kummert, Gabrielle Beaudry, José A. Candanedo et al.
6 citations
Energy and Buildings
Building Energy and Comfort Optimization
6.04
article

A model-based continuous commissioning method for an efficient integration of ground source heat pumps in the building ecosystem

Philippe Pasquier, Michaël Kummert, Gabrielle Beaudry, José A. Candanedo, Giulio Tonellato
article en
6 citations

Abstract

This paper introduces a model-based continuous commissioning (MBCCx) methodology specifically designed for the identification of control-related performance gaps within heating, ventilation and air conditioning (HVAC) systems equipped with ground-source heat pumps (GSHPs). While conventional continuous commissioning (CCx) is effective in detecting energy performance gaps, MBCCx goes further by using a system model as a reference to pinpoint operational inefficiencies and control faults arising from subsystem integration. The core of the proposed methodology lies in a calibrated physics-based model that represents the system performance as intended during the design phase. A key advantage is its applicability early in a building’s operational phase, when data is limited, unlike data-driven methods that rely on extensive historical datasets. This enables the identification of energy-saving opportunities before the system reaches a stable operational state. To address the limitations of prior studies that often focus solely on individual GSHP component performance, this work pioneers the application of MBCCx to whole buildings equipped with GSHPs. The proposed approach employs a detailed 3D building model and component-level HVAC modeling to predict parameters such as room temperatures, heat pump power, and ground heat exchanger temperatures under normal conditions. Significant deviations between monitored values and model predictions serve as indicators of underperforming components or control sequence anomalies. The anomaly detection accuracy is then improved by merging HVAC system and GSHP performance indicators. The methodology is demonstrated through a case study of a recently retrofitted elementary school in Québec, Canada, equipped with five standing column wells as ground heat exchangers.

Energy and BuildingsVol. 333
Natural Sciences and Engineering Research Council of Canada
Life in Land
Openalex Percentile: Top 4%
Building Energy and Comfort Optimization
6.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.