Comparative analysis of the performance and energy consumption of air-conditioning systems in a plant factory during a cooling season

• An energy simulation model of a lettuce-growing container farm was developed. • The performance of EHP-only and EHP with dehumidification systems in a container farm was analyzed. • The EHP with dehumidification system improved cooling and dehumidification performance. • EHP with dehumidification system reduced energy consumption by 5.9%. With the growth of urban populations and increasing food security concerns, plant factories have emerged as viable solutions for sustainable food production. These systems ensure consistent quality and yield through precise environmental controls in a closed system. However, the high energy costs of plant factories pose significant challenges. Heating, ventilation, and air-conditioning systems account for 16–54% of the total energy consumption. Thus, highly efficient systems and optimal control strategies are essential to reduce the energy consumption. This study compared the performance of a conventional electric heat pump system (System 1) with that of a system combining an electric heat pump and a dehumidification unit (System 2) in a lettuce-growing container farm. A building energy simulation model was employed to evaluate system performance. The results indicated that although both systems maintained adequate temperature control, System 1 allowed the relative humidity to reach 95.7%, making it challenging to maintain a suitable environment for crop growth. In contrast, System 2 significantly improved the humidity management, creating a more suitable environment for crop growth and improving the cooling efficiency of the electric heat pump. Consequently, System 2 achieved a 13.7–24.5% reduction in the monthly energy consumption of the electric heat pump. The total annual energy saving of System 2 was 5.9%, accounting for the energy consumption of the dehumidification system. Future research should focus on optimizing the system capacity and control strategies to further maximize the energy savings based on the findings of this study.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2025-02-18
DOI
https://doi.org/10.1016/j.enbuild.2025.115483
Citations
2
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative analysis of the performance and energy consumption of air-conditioning systems in a plant factory during a cooling season

Sang Min Lee, Eun Jung Choi, Doyun Lee
2 citations
Energy and Buildings
Building Energy and Comfort Optimization
2.01
article

Comparative analysis of the performance and energy consumption of air-conditioning systems in a plant factory during a cooling season

Sang Min Lee, Eun Jung Choi, Doyun Lee
article en
2 citations

Abstract

• An energy simulation model of a lettuce-growing container farm was developed. • The performance of EHP-only and EHP with dehumidification systems in a container farm was analyzed. • The EHP with dehumidification system improved cooling and dehumidification performance. • EHP with dehumidification system reduced energy consumption by 5.9%. With the growth of urban populations and increasing food security concerns, plant factories have emerged as viable solutions for sustainable food production. These systems ensure consistent quality and yield through precise environmental controls in a closed system. However, the high energy costs of plant factories pose significant challenges. Heating, ventilation, and air-conditioning systems account for 16–54% of the total energy consumption. Thus, highly efficient systems and optimal control strategies are essential to reduce the energy consumption. This study compared the performance of a conventional electric heat pump system (System 1) with that of a system combining an electric heat pump and a dehumidification unit (System 2) in a lettuce-growing container farm. A building energy simulation model was employed to evaluate system performance. The results indicated that although both systems maintained adequate temperature control, System 1 allowed the relative humidity to reach 95.7%, making it challenging to maintain a suitable environment for crop growth. In contrast, System 2 significantly improved the humidity management, creating a more suitable environment for crop growth and improving the cooling efficiency of the electric heat pump. Consequently, System 2 achieved a 13.7–24.5% reduction in the monthly energy consumption of the electric heat pump. The total annual energy saving of System 2 was 5.9%, accounting for the energy consumption of the dehumidification system. Future research should focus on optimizing the system capacity and control strategies to further maximize the energy savings based on the findings of this study.

Energy and BuildingsVol. 335
Korea Institute of Machinery & Materials (KR)
Affordable and clean energy
Openalex Percentile: Top 16%
Building Energy and Comfort Optimization
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative analysis of the performance and energy consumption of air-conditioning systems in a plant factory during a cooling season — Sang Min Lee, Eun Jung Choi, et al. · Energy and Buildings (2025) | TGRS Research Map | TGRS