SMNS structure based fiber optic interferometer for cadmium detection

A cost-effective, easy-to-manufacture, compact, and reliable single-mode fiber/ multimode fiber/ no-core fiber/ single-mode fiber (SMNS) structure based interferometer is proposed for the detection of cadmium ions (Cd<sup>2+</sup>). This setup involves splicing a segment of multimode fiber (MMF) and no-core fiber (NCF) between a single-mode fiber (SMF), followed by a functionalization procedure with a composite of graphene oxide (GO)-cysteamine (MEA) and chitosan (CS)-Cd<sup>2+</sup> imprinted polymer (Cd<sup>2+</sup>IP). The sensitivity of the sensors has been calculated by monitoring the interference minima. Three identical probes have been fabricated to ensure the duplicability and the highest sensing sensitivity is measured at -0.1211 nm/ parts per billion (ppb) in the cadmium detection range of 0 ppb to 10 ppb with a response time of 90 s. The probe demonstrates a high selectivity for Cd<sup>2+</sup> compared to other heavy metal ions. The response of the probe in various pH solutions has been investigated to minimize the sensing error. Further, the temperature crosstalk is eliminated by assessing the response of a fiber Bragg grating (FBG).

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-02-18
DOI
https://doi.org/10.1364/oe.547717
Citations
1
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SMNS structure based fiber optic interferometer for cadmium detection

Xujie Wang, Yifan Liu, Abdullah Al Noman, Changyuan Yu
1 citations
Optics Express
Electrochemical Analysis and Applications
0.52
article

SMNS structure based fiber optic interferometer for cadmium detection

Xujie Wang, Yifan Liu, Abdullah Al Noman, Changyuan Yu
article en
1 citations

Abstract

A cost-effective, easy-to-manufacture, compact, and reliable single-mode fiber/ multimode fiber/ no-core fiber/ single-mode fiber (SMNS) structure based interferometer is proposed for the detection of cadmium ions (Cd<sup>2+</sup>). This setup involves splicing a segment of multimode fiber (MMF) and no-core fiber (NCF) between a single-mode fiber (SMF), followed by a functionalization procedure with a composite of graphene oxide (GO)-cysteamine (MEA) and chitosan (CS)-Cd<sup>2+</sup> imprinted polymer (Cd<sup>2+</sup>IP). The sensitivity of the sensors has been calculated by monitoring the interference minima. Three identical probes have been fabricated to ensure the duplicability and the highest sensing sensitivity is measured at -0.1211 nm/ parts per billion (ppb) in the cadmium detection range of 0 ppb to 10 ppb with a response time of 90 s. The probe demonstrates a high selectivity for Cd<sup>2+</sup> compared to other heavy metal ions. The response of the probe in various pH solutions has been investigated to minimize the sensing error. Further, the temperature crosstalk is eliminated by assessing the response of a fiber Bragg grating (FBG).

Optics ExpressVol. 33(8)
University of Limerick (IE)
University Grants Committee
Openalex Percentile: Top 47%
Electrochemical Analysis and Applications
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.