Effect of non-uniform nanofluid concentration on interferometric heat transfer measurements

The effect of non-uniform nanofluid concentration on the accuracy of interferometric heat transfer measurements has been investigated using a Mach-Zehnder interferometer. Because the refractive index is a function of concentration as well as temperature, concentration variations within the nanofluid can produce unwanted interference fringes, leading to temperature measurement errors. Measurement errors in the temperature gradient are demonstrated for conduction within a cavity heated from top to bottom, filled with an Al 2 O 3 -water nanofluid (0.16 wt%) produced using a standard two-step method. The results of the current measurements show that the temperature gradient can be overestimated by up to 100 % due to near-wall concentration gradients in an unstable nanofluid. The measurement problem is delineated, and several approaches to mitigate this source of measurement error are outlined. The technical trade-offs associated with designing interferometric heat transfer experiments to reduce the sensitivity to concentration differences are discussed. These trade-offs include selecting the nanofluid type and concentration, temperature differences, and the optical path length of the experimental model. It is shown that many interferometric studies in the literature were much more sensitive to concentration-induced errors than the current experiment. An isothermal stability test is recommended to detect nanofluid concentration gradients prior to temperature-based interferometry experiments. • Homogeneous nanofluids are critical for temperature-based interferometry. • Unstable nanofluids can cause large heat flux measurement errors. • A concentration sensitivity parameter is proposed. • Mitigation of concentration errors in interferometry is discussed.

Authors

Institutions

Publication Details

Journal
International Journal of Thermal Sciences
Published
2025-02-18
DOI
https://doi.org/10.1016/j.ijthermalsci.2025.109802
Citations
2
Primary Topic
Nanofluid Flow and Heat Transfer
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of non-uniform nanofluid concentration on interferometric heat transfer measurements

David Naylor, S. Sahamifar, J. Friedman
2 citations
International Journal of Thermal Sciences
Nanofluid Flow and Heat Transfer
1.35
article

Effect of non-uniform nanofluid concentration on interferometric heat transfer measurements

David Naylor, S. Sahamifar, J. Friedman
article en
2 citations

Abstract

The effect of non-uniform nanofluid concentration on the accuracy of interferometric heat transfer measurements has been investigated using a Mach-Zehnder interferometer. Because the refractive index is a function of concentration as well as temperature, concentration variations within the nanofluid can produce unwanted interference fringes, leading to temperature measurement errors. Measurement errors in the temperature gradient are demonstrated for conduction within a cavity heated from top to bottom, filled with an Al 2 O 3 -water nanofluid (0.16 wt%) produced using a standard two-step method. The results of the current measurements show that the temperature gradient can be overestimated by up to 100 % due to near-wall concentration gradients in an unstable nanofluid. The measurement problem is delineated, and several approaches to mitigate this source of measurement error are outlined. The technical trade-offs associated with designing interferometric heat transfer experiments to reduce the sensitivity to concentration differences are discussed. These trade-offs include selecting the nanofluid type and concentration, temperature differences, and the optical path length of the experimental model. It is shown that many interferometric studies in the literature were much more sensitive to concentration-induced errors than the current experiment. An isothermal stability test is recommended to detect nanofluid concentration gradients prior to temperature-based interferometry experiments. • Homogeneous nanofluids are critical for temperature-based interferometry. • Unstable nanofluids can cause large heat flux measurement errors. • A concentration sensitivity parameter is proposed. • Mitigation of concentration errors in interferometry is discussed.

International Journal of Thermal SciencesVol. 212
University of Toronto (CA)
Openalex Percentile: Top 22%
Nanofluid Flow and Heat Transfer
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of non-uniform nanofluid concentration on interferometric heat transfer measurements — David Naylor, S. Sahamifar, et al. · International Journal of Thermal Sciences (2025) | TGRS Research Map | TGRS