Histopathological findings of biodegradable polymer sirolimus eluting stent 7 years after stent implantation
A 65-year-old male received three 3rd generation biodegradable polymer coated drug-eluting stents (BP-DES), Ultimaster (Terumo, Tokyo, Japan), during percutaneous coronary intervention. Seven years post-implantation, post-mortem histopathological analysis revealed well-healed arterial tissue with near-complete endothelialization and minimal neoatherosclerosis. No significant inflammation or late stent thrombosis was observed, with stent struts embedded in the neointima, indicating favorable long-term vessel healing. This case underscores the long-term biocompatibility of BP-DES, highlighting reduced risks of late stent thrombosis and neointimal hyperplasia over extended follow-up periods.
Authors
- Yo Kawahara
- Gaku Nakazawa (ORCID: https://orcid.org/0000-0002-6721-1342)
- Sho Torii (ORCID: https://orcid.org/0000-0002-5934-0427)
- Yasutomo Sekido
Institutions
- Tokai University (JP)
- Tokai University Hospital (JP)
- Kindai University (JP)
Publication Details
- Journal
- Journal of Cardiology Cases
- Published
- 2025-02-18
- DOI
- https://doi.org/10.1016/j.jccase.2025.01.007
- Primary Topic
- Coronary Interventions and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Japanese Association of Cardiovascular Intervention and Therapeutics
- Japan Society for the Promotion of Science
- School of Medicine, Tokai University