Smart Arrhythmia Detection Using Single Lead ECG Signal and Hybridized Deep Neural Network Model

Arrhythmia is an irregular electrical activity of the heart that needs to be treated quickly and promptly to avoid the risk of cardiac failure and stroke. Signal processing utilizing Electrocardiogram (ECG) signals continues to be the gold standard for detecting cardiac abnormalities. However, the low classification accuracy and lack of labeled ECG data might seriously impair the existing algorithm's overall performance. To address the drawbacks of the existing techniques, the proposed research utilizes a deep learning model formulated utilizing the cephalous wolf optimization-based deep neural network model (CWO opt NN) for effective arrhythmia detection. The proposed model leverages the characteristics of a single lead ECG database to retrieve the input data initially. Next, the signal is preprocessed by adopting the window sliding approach to eliminate any potential noise. In addition, the extracted time-domain features, frequency domain features, geometrical features, CSI-CVI features, wavelet features, and statistical features, aid in boosting the accuracy of arrhythmia detection. To accurately identify arrhythmia, the developed model explores the Neural Networks for learning the cardiac cycles effectively. Specifically, cephalous wolf optimization, developed by the typical hybridization of the cephalous wolf and wolf hawk, is essential to the research's relevance since it allows for the successful identification of arrhythmia by fine-tuning the classifier's weights and bias. Considering the achievement rates for arrhythmia identification at training percentage 80, the F1-score is 96.10%, precision is 97.08%, and recall is 95.14% respectively, similarly based on the k-fold 8, F1-score is 96.10%, precision is 96.80%, and recall is 94.86% respectively.

Authors

Publication Details

Journal
Web Intelligence
Published
2025-02-18
DOI
https://doi.org/10.1177/24056456241297300
Citations
5
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
6.94
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smart Arrhythmia Detection Using Single Lead ECG Signal and Hybridized Deep Neural Network Model

A. N. Paithane, Poonam Lambhate, Aparna Hambarde, Shailesh Hambarde et al.
5 citations
Web Intelligence
ECG Monitoring and Analysis
6.94
article

Smart Arrhythmia Detection Using Single Lead ECG Signal and Hybridized Deep Neural Network Model

A. N. Paithane, Poonam Lambhate, Aparna Hambarde, Shailesh Hambarde, Pratima Amol Kalyankar
article en
5 citations

Abstract

Arrhythmia is an irregular electrical activity of the heart that needs to be treated quickly and promptly to avoid the risk of cardiac failure and stroke. Signal processing utilizing Electrocardiogram (ECG) signals continues to be the gold standard for detecting cardiac abnormalities. However, the low classification accuracy and lack of labeled ECG data might seriously impair the existing algorithm's overall performance. To address the drawbacks of the existing techniques, the proposed research utilizes a deep learning model formulated utilizing the cephalous wolf optimization-based deep neural network model (CWO opt NN) for effective arrhythmia detection. The proposed model leverages the characteristics of a single lead ECG database to retrieve the input data initially. Next, the signal is preprocessed by adopting the window sliding approach to eliminate any potential noise. In addition, the extracted time-domain features, frequency domain features, geometrical features, CSI-CVI features, wavelet features, and statistical features, aid in boosting the accuracy of arrhythmia detection. To accurately identify arrhythmia, the developed model explores the Neural Networks for learning the cardiac cycles effectively. Specifically, cephalous wolf optimization, developed by the typical hybridization of the cephalous wolf and wolf hawk, is essential to the research's relevance since it allows for the successful identification of arrhythmia by fine-tuning the classifier's weights and bias. Considering the achievement rates for arrhythmia identification at training percentage 80, the F1-score is 96.10%, precision is 97.08%, and recall is 95.14% respectively, similarly based on the k-fold 8, F1-score is 96.10%, precision is 96.80%, and recall is 94.86% respectively.

Web IntelligenceVol. 23(2)
Openalex Percentile: Top 3%
ECG Monitoring and Analysis
6.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.