Retrospective Analysis of Dental Implant Stability in Relation to Mandibular Bone Density and Cortical Thickness in Osteopenic and Osteoporotic Patients

<b>Background/Objectives:</b> The aim of this study is to examine the relationship between cervical spine and jaw bone mineral density (BMD) and assess how cortical thickness and BMD influence primary implant stability (PIS) across different bone health conditions. <b>Methods:</b> The study included 29 patients (mean age: 63.7 ± 13.7 years; 13 women) and 15 healthy controls (mean age: 25.3 ± 3.0 years; seven women). Cervical spine (C2-C4) and mandibular BMD were evaluated using asynchronous calibration and manual segmentation. Cortical thickness was measured, and primary implant stability was assessed via insertion torque in Newton centimeters (Ncm). <b>Results:</b> Cervical spine BMD was significantly lower in the patient group compared to controls (203.0 ± 51.0 vs. 252.0 ± 21.7 mg/dL, <i>p</i> < 0.0001). No significant correlation was found between mandibular BMD and cervical spine BMD in both groups (patients: ρ = 0.1287; <i>p</i> = 0.506, controls r = -0.1214; <i>p</i> = 0.667). Linear regression analysis revealed that cortical thickness alone, not implant site BMD, significantly influenced PIS (F(2.74) = 5.597, <i>p</i> = 0.005). <b>Conclusions:</b> Asynchronous calibration accurately quantifies cervical and mandibular BMD. Cortical thickness rather than overall bone density emerges as a critical factor in determining implant stability. These findings suggest that clinicians should prioritize cortical thickness assessment when planning dental implant procedures, potentially improving outcomes across diverse patient bone health profiles.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-02-18
DOI
https://doi.org/10.3390/jcm14041339
Citations
2
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
3.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrospective Analysis of Dental Implant Stability in Relation to Mandibular Bone Density and Cortical Thickness in Osteopenic and Osteoporotic Patients

Egon Burian, Thomas Frauenfelder, Florian Probst, Monika Probst et al.
2 citations
Journal of Clinical Medicine
Bone health and osteoporosis research
3.44
article

Retrospective Analysis of Dental Implant Stability in Relation to Mandibular Bone Density and Cortical Thickness in Osteopenic and Osteoporotic Patients

Egon Burian, Thomas Frauenfelder, Florian Probst, Monika Probst, Gustav Andreisek, Alexander Wolfgang Marka, Matthias Tröltzsch, Matthias Bruckbauer
article en
2 citations

Abstract

<b>Background/Objectives:</b> The aim of this study is to examine the relationship between cervical spine and jaw bone mineral density (BMD) and assess how cortical thickness and BMD influence primary implant stability (PIS) across different bone health conditions. <b>Methods:</b> The study included 29 patients (mean age: 63.7 ± 13.7 years; 13 women) and 15 healthy controls (mean age: 25.3 ± 3.0 years; seven women). Cervical spine (C2-C4) and mandibular BMD were evaluated using asynchronous calibration and manual segmentation. Cortical thickness was measured, and primary implant stability was assessed via insertion torque in Newton centimeters (Ncm). <b>Results:</b> Cervical spine BMD was significantly lower in the patient group compared to controls (203.0 ± 51.0 vs. 252.0 ± 21.7 mg/dL, <i>p</i> < 0.0001). No significant correlation was found between mandibular BMD and cervical spine BMD in both groups (patients: ρ = 0.1287; <i>p</i> = 0.506, controls r = -0.1214; <i>p</i> = 0.667). Linear regression analysis revealed that cortical thickness alone, not implant site BMD, significantly influenced PIS (F(2.74) = 5.597, <i>p</i> = 0.005). <b>Conclusions:</b> Asynchronous calibration accurately quantifies cervical and mandibular BMD. Cortical thickness rather than overall bone density emerges as a critical factor in determining implant stability. These findings suggest that clinicians should prioritize cortical thickness assessment when planning dental implant procedures, potentially improving outcomes across diverse patient bone health profiles.

Journal of Clinical MedicineVol. 14(4)
University of Salzburg (AT), University of Zurich (CH), TUM Klinikum (DE), University Hospital of Zurich (CH), Kantonsspital Frauenfeld (CH), Technical University of Munich (DE), Ludwig-Maximilians-Universität München (DE)
Technische Universität München
Openalex Percentile: Top 11%
Bone health and osteoporosis research
3.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.