Feasibility study of skin dosimetry with TLD sheets for measuring the effect of 3D printed bolus in radiotherapy

The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese-doped LiB<sub>3</sub>O<sub>5</sub> in sheet form. The sheet is 0.2-mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets. Further, the surface doses when using a three-dimensional (3D) printed bolus were compared. First, calibration of the between TLD sheet measurements and the irradiation doses was performed. Second, dose calculations and TLD sheet measurements were compared to evaluate the error between treatment planning system (TPS) dose calculations and surface dose measurements. Finally, the TLD sheet was fitted to the head phantom to measure the surface dose at the uneven areas under two conditions (with a commercial [CM] bolus and a 3D-printed bolus). Based on the error from the dose calculation algorithm and the difference between the TLD sheet thickness and the dose grid size or evaluation structure volume, the differences between the TLD sheet measurements and the treatment plan doses were up to 68.6% for the X-ray collapsed cone convolution (CCC) method and up to 8.4% for the electron beam Monte Carlo (MC) method. Based on the results of the surface dosimetry of the head phantom, the application of surface dosimetry, particularly skin dosimetry, even on uneven body surfaces, can be feasible.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2025-02-18
DOI
https://doi.org/10.1002/acm2.70035
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility study of skin dosimetry with TLD sheets for measuring the effect of 3D printed bolus in radiotherapy

Hikaru Souda, Yoshifumi Yamazawa, Akira Takagi, Miyu Ishizawa et al.
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
article

Feasibility study of skin dosimetry with TLD sheets for measuring the effect of 3D printed bolus in radiotherapy

Hikaru Souda, Yoshifumi Yamazawa, Akira Takagi, Miyu Ishizawa, Hiraku Sato, Takeo Iwai, Hongbo Chai, Mayumi Ichikawa, Yuya Miyasaka
article en

Abstract

The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese-doped LiB<sub>3</sub>O<sub>5</sub> in sheet form. The sheet is 0.2-mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets. Further, the surface doses when using a three-dimensional (3D) printed bolus were compared. First, calibration of the between TLD sheet measurements and the irradiation doses was performed. Second, dose calculations and TLD sheet measurements were compared to evaluate the error between treatment planning system (TPS) dose calculations and surface dose measurements. Finally, the TLD sheet was fitted to the head phantom to measure the surface dose at the uneven areas under two conditions (with a commercial [CM] bolus and a 3D-printed bolus). Based on the error from the dose calculation algorithm and the difference between the TLD sheet thickness and the dose grid size or evaluation structure volume, the differences between the TLD sheet measurements and the treatment plan doses were up to 68.6% for the X-ray collapsed cone convolution (CCC) method and up to 8.4% for the electron beam Monte Carlo (MC) method. Based on the results of the surface dosimetry of the head phantom, the application of surface dosimetry, particularly skin dosimetry, even on uneven body surfaces, can be feasible.

Journal of Applied Clinical Medical PhysicsVol. 26(5)
Yamagata University (JP), Yamagata University Hospital (JP)
Openalex Percentile: Top 96%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Feasibility study of skin dosimetry with TLD sheets for measuring the effect of 3D printed bolus in radiotherapy — Hikaru Souda, Yoshifumi Yamazawa, et al. · Journal of Applied Clinical Medical Physics (2025) | TGRS Research Map | TGRS