Comparison of the transradial and transfemoral approaches for uterine artery embolization: a randomized clinical trial

BackgroundUterine artery embolization (UAE) is a procedure commonly used to control uterine bleeding or pain. While the procedure is traditionally performed through the transfemoral approach (TFA), the transradial approach (TRA) is another method.PurposeTo compare the effectiveness of the UAE using the TRA approach versus the TFA approach.Material and MethodsThis non-blinded, randomized clinical trial was conducted at a tertiary hospital between 1 January 2019 and 30 June 2022. A total of 42 female patients with abnormal uterine bleeding and/or pelvic pain from uterine fibroids were randomly assigned to either the TRA group or the TFA group. Data collected included demographic information, procedural details, patient satisfaction, and radiation metrics.ResultsThe TRA group had significantly lower numbers of microsphere vials used compared to the TFA group (<i>P</i> = 0.014). While there were no significant differences in procedure times (<i>P</i> = 0.058), fluoroscopic times (<i>P</i> = 0.117), or radiation doses (<i>P</i> = 0.466), the TRA approach was associated with a higher success rate in achieving bilateral UA catheterization and fewer instances of bilateral sheath insertion. Patient satisfaction scores were similar between the groups, with no statistically significant difference (<i>P</i> = 0.932). Minor adverse events such as local hematoma and color changes were more frequent in the TFA group, though these differences were not statistically significant.ConclusionAlthough both approaches were effective for the UAE, the TRA approach may be a viable alternative to the TFA due to its higher success rate in achieving bilateral catheterization, lower radiation doses, and shorter procedural times.

Authors

Institutions

Publication Details

Journal
Acta Radiologica
Published
2025-02-01
DOI
https://doi.org/10.1177/02841851241297818
Citations
2
Primary Topic
Vascular Procedures and Complications
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the transradial and transfemoral approaches for uterine artery embolization: a randomized clinical trial

Ahmed Awad Bessar, Ahmed Ismail Heraiz, Maichael Talaat, Yasmin Ibrahim Libda et al.
2 citations
Acta Radiologica
Vascular Procedures and Complications
3.04
article

Comparison of the transradial and transfemoral approaches for uterine artery embolization: a randomized clinical trial

Ahmed Awad Bessar, Ahmed Ismail Heraiz, Maichael Talaat, Yasmin Ibrahim Libda, Manar A. Bessar, Enjy Fathy Tantawy
article en
2 citations

Abstract

BackgroundUterine artery embolization (UAE) is a procedure commonly used to control uterine bleeding or pain. While the procedure is traditionally performed through the transfemoral approach (TFA), the transradial approach (TRA) is another method.PurposeTo compare the effectiveness of the UAE using the TRA approach versus the TFA approach.Material and MethodsThis non-blinded, randomized clinical trial was conducted at a tertiary hospital between 1 January 2019 and 30 June 2022. A total of 42 female patients with abnormal uterine bleeding and/or pelvic pain from uterine fibroids were randomly assigned to either the TRA group or the TFA group. Data collected included demographic information, procedural details, patient satisfaction, and radiation metrics.ResultsThe TRA group had significantly lower numbers of microsphere vials used compared to the TFA group (<i>P</i> = 0.014). While there were no significant differences in procedure times (<i>P</i> = 0.058), fluoroscopic times (<i>P</i> = 0.117), or radiation doses (<i>P</i> = 0.466), the TRA approach was associated with a higher success rate in achieving bilateral UA catheterization and fewer instances of bilateral sheath insertion. Patient satisfaction scores were similar between the groups, with no statistically significant difference (<i>P</i> = 0.932). Minor adverse events such as local hematoma and color changes were more frequent in the TFA group, though these differences were not statistically significant.ConclusionAlthough both approaches were effective for the UAE, the TRA approach may be a viable alternative to the TFA due to its higher success rate in achieving bilateral catheterization, lower radiation doses, and shorter procedural times.

Acta RadiologicaVol. 66(2)
Zagazig University (EG), Sorbonne Université (FR), Assistance Publique – Hôpitaux de Paris (FR), Pitié-Salpêtrière Hospital (FR)
Good health and well-being
Openalex Percentile: Top 11%
Vascular Procedures and Complications
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.