Imageless optical navigation system is clinically valid for total knee arthroplasty

Achieving optimal implant position and orientation during total knee arthroplasty (TKA) is a pivotal factor in long-term survival. Computer-assisted navigation (CAN) has been recognized as a trusted technology that improves the accuracy and consistency of femoral and tibial bone cuts. Imageless CAN offers advantages over image-based CAN by reducing cost, radiation exposure, and time. The purpose of this study was to evaluate the accuracy of an imageless optical navigation system for TKA in a clinical setting. Forty-two consecutive patients who underwent primary TKA with CAN were retrospectively reviewed. Femoral and tibial component coronal alignment was assessed <i>via</i> post-operative radiographs by two independent reviewers and compared against coronal alignment angles from the CAN. The primary outcome was the mean absolute difference of femoral and tibial varus/valgus angles between radiograph and intra-operative device measurements. Bland-Altman plots were used to assess agreement between the methods and statistically analyze potential systematic bias. The mean absolute differences between navigation-guided cut measurements and post-operative radiographs were 1.16 ± 1.03° and 1.76 ± 1.38° for femoral and tibial alignment respectively. About 88% of coronal measurements were within ±3°, while 99% were within ±5°. Bland-Altman analysis demonstrated a bias between CAN and radiographic measurements with CAN values averaging 0.52° (95% CI: 0.11°-0.93°) less than their paired radiographic measurements. This study demonstrated the ability of an optical imageless navigation system to measure, on average, femoral and tibial coronal cuts to within 2.0° of post-operative radiographic measurements in a clinical setting.

Authors

Institutions

Publication Details

Journal
Computer Assisted Surgery
Published
2025-02-16
DOI
https://doi.org/10.1080/24699322.2025.2466424
Citations
1
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Imageless optical navigation system is clinically valid for total knee arthroplasty

Taylor B. Winberg, Sheila Wang, James L. Howard
1 citations
Computer Assisted Surgery
Total Knee Arthroplasty Outcomes
2.01
article

Imageless optical navigation system is clinically valid for total knee arthroplasty

Taylor B. Winberg, Sheila Wang, James L. Howard
article en
1 citations

Abstract

Achieving optimal implant position and orientation during total knee arthroplasty (TKA) is a pivotal factor in long-term survival. Computer-assisted navigation (CAN) has been recognized as a trusted technology that improves the accuracy and consistency of femoral and tibial bone cuts. Imageless CAN offers advantages over image-based CAN by reducing cost, radiation exposure, and time. The purpose of this study was to evaluate the accuracy of an imageless optical navigation system for TKA in a clinical setting. Forty-two consecutive patients who underwent primary TKA with CAN were retrospectively reviewed. Femoral and tibial component coronal alignment was assessed <i>via</i> post-operative radiographs by two independent reviewers and compared against coronal alignment angles from the CAN. The primary outcome was the mean absolute difference of femoral and tibial varus/valgus angles between radiograph and intra-operative device measurements. Bland-Altman plots were used to assess agreement between the methods and statistically analyze potential systematic bias. The mean absolute differences between navigation-guided cut measurements and post-operative radiographs were 1.16 ± 1.03° and 1.76 ± 1.38° for femoral and tibial alignment respectively. About 88% of coronal measurements were within ±3°, while 99% were within ±5°. Bland-Altman analysis demonstrated a bias between CAN and radiographic measurements with CAN values averaging 0.52° (95% CI: 0.11°-0.93°) less than their paired radiographic measurements. This study demonstrated the ability of an optical imageless navigation system to measure, on average, femoral and tibial coronal cuts to within 2.0° of post-operative radiographic measurements in a clinical setting.

Computer Assisted SurgeryVol. 30(1)
London Health Sciences Centre (CA), Intellijoint Surgical (Canada) (CA)
Openalex Percentile: Top 19%
Total Knee Arthroplasty Outcomes
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Imageless optical navigation system is clinically valid for total knee arthroplasty — Taylor B. Winberg, Sheila Wang, et al. · Computer Assisted Surgery (2025) | TGRS Research Map | TGRS