High-Pulse-Repetition-Rate Eye-Safe Raman Laser with Acousto-Optic Q-Switched Device

The acousto-optic Q-switch is exploited to develop a high-repetition-rate eye-safe Raman laser at 1526 nm. The Nd:YVO<sub>4</sub> and KGW crystals are employed as the fundamental laser and Stokes Raman gain materials, respectively. The influence of the gate-open time on the performance is systematically explored for the repetition rate between 80 and 150 kHz. The separate configuration is used to construct the resonant cavities for the fundamental and Stokes waves to achieve a pulse width that is as short as possible. Under the optimal alignment, the average output power can exceed 5.0 W at a pump power of 30 W for a repetition rate within 100-150 kHz with a gate-open time of 0.5 μs. In addition, the output peak power can be greater than 10 kW for a pulse repetition rate between 80 and 120 kHz. The optical-to-optical conversion efficiency is up to 16.7%, which is better than that obtained by the Nd:YVO<sub>4</sub>/YVO<sub>4</sub> system.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-02-16
DOI
https://doi.org/10.3390/mi16020222
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Pulse-Repetition-Rate Eye-Safe Raman Laser with Acousto-Optic Q-Switched Device

Y. F. Chen, Hsing-Chih Liang, Dai-Jun Liu, Songqing Lin et al.
1 citations
Micromachines
Photoacoustic and Ultrasonic Imaging
0.67
article

High-Pulse-Repetition-Rate Eye-Safe Raman Laser with Acousto-Optic Q-Switched Device

Y. F. Chen, Hsing-Chih Liang, Dai-Jun Liu, Songqing Lin, Yu‐Hsin Hsu
article en
1 citations

Abstract

The acousto-optic Q-switch is exploited to develop a high-repetition-rate eye-safe Raman laser at 1526 nm. The Nd:YVO<sub>4</sub> and KGW crystals are employed as the fundamental laser and Stokes Raman gain materials, respectively. The influence of the gate-open time on the performance is systematically explored for the repetition rate between 80 and 150 kHz. The separate configuration is used to construct the resonant cavities for the fundamental and Stokes waves to achieve a pulse width that is as short as possible. Under the optimal alignment, the average output power can exceed 5.0 W at a pump power of 30 W for a repetition rate within 100-150 kHz with a gate-open time of 0.5 μs. In addition, the output peak power can be greater than 10 kW for a pulse repetition rate between 80 and 120 kHz. The optical-to-optical conversion efficiency is up to 16.7%, which is better than that obtained by the Nd:YVO<sub>4</sub>/YVO<sub>4</sub> system.

MicromachinesVol. 16(2)
National Yang Ming Chiao Tung University (TW)
National Science and Technology Council
Openalex Percentile: Top 35%
Photoacoustic and Ultrasonic Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.