Study on Liquid Metal Embrittlement Susceptibility of T91 Exposed to Liquid Lead-Bismuth Eutectic

In this study, slow strain rate tensile tests (SSRT) were performed on T91 in lead-bismuth eutectic (LBE) with saturated oxygen to investigate the effects of temperature (350 °C, 450 °C, and 550 °C), strain rate (1 × 10−5/s and 2 × 10−6/s) and pre-exposure conditions (time, oxygen concentration) on the sensitivity to liquid metal embrittlement (LME). The results revealed that the embrittlement sensitivity of T91 in LBE is significantly influenced by temperature. LME was observed in T91 at 350 °C and disappeared when the temperature increased to 550 °C. Additionally, T91 exhibited increased sensitivity to LME at low strain rates, indicating that low strain rates promoted the occurrence of LME. Finally, through different pre-exposure conditions, it was found that the obvious LME phenomenon would only occur when the oxygen concentration was poor and the pre-exposure time was long (48 h), indicating that pre-exposure conditions have a crucial impact on the occurrence of LME.

Authors

Institutions

Publication Details

Journal
Metals
Published
2025-02-15
DOI
https://doi.org/10.3390/met15020206
Citations
2
Primary Topic
Nuclear Materials and Properties
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Liquid Metal Embrittlement Susceptibility of T91 Exposed to Liquid Lead-Bismuth Eutectic

Bin Long, Bo Qin, Jie Zhang
2 citations
Metals
Nuclear Materials and Properties
1.04
article

Study on Liquid Metal Embrittlement Susceptibility of T91 Exposed to Liquid Lead-Bismuth Eutectic

Bin Long, Bo Qin, Jie Zhang
article en
2 citations

Abstract

In this study, slow strain rate tensile tests (SSRT) were performed on T91 in lead-bismuth eutectic (LBE) with saturated oxygen to investigate the effects of temperature (350 °C, 450 °C, and 550 °C), strain rate (1 × 10−5/s and 2 × 10−6/s) and pre-exposure conditions (time, oxygen concentration) on the sensitivity to liquid metal embrittlement (LME). The results revealed that the embrittlement sensitivity of T91 in LBE is significantly influenced by temperature. LME was observed in T91 at 350 °C and disappeared when the temperature increased to 550 °C. Additionally, T91 exhibited increased sensitivity to LME at low strain rates, indicating that low strain rates promoted the occurrence of LME. Finally, through different pre-exposure conditions, it was found that the obvious LME phenomenon would only occur when the oxygen concentration was poor and the pre-exposure time was long (48 h), indicating that pre-exposure conditions have a crucial impact on the occurrence of LME.

MetalsVol. 15(2)
China Institute of Atomic Energy (CN)
China National Nuclear Corporation
Openalex Percentile: Top 28%
Nuclear Materials and Properties
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on Liquid Metal Embrittlement Susceptibility of T91 Exposed to Liquid Lead-Bismuth Eutectic — Bin Long, Bo Qin, et al. · Metals (2025) | TGRS Research Map | TGRS