Numerical Study of Perforated Plate Balanced Flowmeter Performance for Liquid Hydrogen

A balanced flowmeter not only inherits the advantages of orifice plate flowmeters but also stabilizes the flow field, reduces permanent pressure loss, and effectively increases the cavitation threshold. To perform an in-depth analysis of flow characteristics through the perforated plate and achieve performance optimization for the liquid hydrogen (LH2) measurement, a numerical calculation framework is established based on the mixture model, realizable turbulence closure, and Schnerr–Sauer cavitation model. The model is first evaluated through comparison with the liquid nitrogen (LN2) experimental results of a self-developed balanced flowmeter as well as the measuring setup. The flow coefficient and pressure loss coefficient are especially considered, and a comparison is made with the orifice plane considering cavitation and non-cavitation conditions. The cavitation cloud and temperature contours are also presented to illustrate the difference in the upper limit of the Re between water, LN2, and LH2 flow. The results show that compared to LN2 and water, LH2 has a larger cavitation threshold, indicating a wider range of Re number measurements.

Authors

Institutions

Publication Details

Journal
Cryo
Published
2025-02-16
DOI
https://doi.org/10.3390/cryo1010003
Citations
1
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Study of Perforated Plate Balanced Flowmeter Performance for Liquid Hydrogen

Shiyao Peng, Feng Zhao, Xiaobin Zhang, Jun Jun Song
1 citations
Cryo
Flow Measurement and Analysis
0.86
article

Numerical Study of Perforated Plate Balanced Flowmeter Performance for Liquid Hydrogen

Shiyao Peng, Feng Zhao, Xiaobin Zhang, Jun Jun Song
article en
1 citations

Abstract

A balanced flowmeter not only inherits the advantages of orifice plate flowmeters but also stabilizes the flow field, reduces permanent pressure loss, and effectively increases the cavitation threshold. To perform an in-depth analysis of flow characteristics through the perforated plate and achieve performance optimization for the liquid hydrogen (LH2) measurement, a numerical calculation framework is established based on the mixture model, realizable turbulence closure, and Schnerr–Sauer cavitation model. The model is first evaluated through comparison with the liquid nitrogen (LN2) experimental results of a self-developed balanced flowmeter as well as the measuring setup. The flow coefficient and pressure loss coefficient are especially considered, and a comparison is made with the orifice plane considering cavitation and non-cavitation conditions. The cavitation cloud and temperature contours are also presented to illustrate the difference in the upper limit of the Re between water, LN2, and LH2 flow. The results show that compared to LN2 and water, LH2 has a larger cavitation threshold, indicating a wider range of Re number measurements.

CryoVol. 1(1)
Shanghai Institute for Science of Science (CN), Zhejiang University (CN)
Openalex Percentile: Top 34%
Flow Measurement and Analysis
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.