Simultaneous partial discharge and current measurements in a needle-plane configuration at different pressures

Abstract Phase-resolved partial discharge (PRPD) measurement has been used for decades as a method of monitoring defects in electrically insulating materials. More recently, it has seen a renewed interest in the context of flash sintering, a novel ceramic densification process where the sample to be densified is subjected to an electric field in addition to the usual application of heat. In the context of flash sintering, the monitoring of partial discharge (PD) activity has shown that this activity increases when approaching the onset of the thermal runaway phenomenon leading to the quick densification of the material, and is influenced by environmental factors such as relative humidity or pressure. A new microcontroller-based PRPD measurement system architecture has recently been proposed as a means to explore this PD activity in further details. While PDRD measurement is traditionally carried out by comparing the measured partial discharge pattern to the waveform of the voltage applied to the device under test (DUT), we show in this work that expanding this bespoke measurement system to be able to simultaneously monitor the waveform of the current going through the DUT allows for the collection of data related to the electrical power transferred to the DUT during the process that displays peculiar features. In the present work, the DUT consists of a classical needle-plane setup. As pressure decreases down from atmospheric levels, the threshold voltage leading up to the apparition of discharges decreases following a trend similar to the classical Paschen curve. Additionally, the nature of the discharge activity transitions from low-amplitude, rapid-firing tightly packed trains of pulses to high-amplitude, longer-lasting and more spread out pulses. Simultaneous measurement of the discharges, applied voltage and current going through the DUT shows that this second type of discharge activity can be synchronous with an asymmetric, distorted current waveform having the same period as the applied voltage, corresponding to a transfer of active electrical power into the DUT. Furthermore, the width of these current waveforms expands as the applied voltage is increased progressively starting from the threshold voltage for the activation of discharge activity, indicating that the rate of total power transferred in the DUT may be tuned using the amplitude of the applied voltage. External confirmation of a significant power transfer taking place in these conditions is obtained through the observation of damage inflicted on the DUT after a period of sustained discharge activity at low pressure.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-02-01
DOI
https://doi.org/10.1088/1742-6596/2952/1/012008
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous partial discharge and current measurements in a needle-plane configuration at different pressures

Philippe Vanderbemden, Jean-François Fagnard, Thomas Gillis
Journal of Physics Conference Series
High voltage insulation and dielectric phenomena
article

Simultaneous partial discharge and current measurements in a needle-plane configuration at different pressures

Philippe Vanderbemden, Jean-François Fagnard, Thomas Gillis
article en

Abstract

Abstract Phase-resolved partial discharge (PRPD) measurement has been used for decades as a method of monitoring defects in electrically insulating materials. More recently, it has seen a renewed interest in the context of flash sintering, a novel ceramic densification process where the sample to be densified is subjected to an electric field in addition to the usual application of heat. In the context of flash sintering, the monitoring of partial discharge (PD) activity has shown that this activity increases when approaching the onset of the thermal runaway phenomenon leading to the quick densification of the material, and is influenced by environmental factors such as relative humidity or pressure. A new microcontroller-based PRPD measurement system architecture has recently been proposed as a means to explore this PD activity in further details. While PDRD measurement is traditionally carried out by comparing the measured partial discharge pattern to the waveform of the voltage applied to the device under test (DUT), we show in this work that expanding this bespoke measurement system to be able to simultaneously monitor the waveform of the current going through the DUT allows for the collection of data related to the electrical power transferred to the DUT during the process that displays peculiar features. In the present work, the DUT consists of a classical needle-plane setup. As pressure decreases down from atmospheric levels, the threshold voltage leading up to the apparition of discharges decreases following a trend similar to the classical Paschen curve. Additionally, the nature of the discharge activity transitions from low-amplitude, rapid-firing tightly packed trains of pulses to high-amplitude, longer-lasting and more spread out pulses. Simultaneous measurement of the discharges, applied voltage and current going through the DUT shows that this second type of discharge activity can be synchronous with an asymmetric, distorted current waveform having the same period as the applied voltage, corresponding to a transfer of active electrical power into the DUT. Furthermore, the width of these current waveforms expands as the applied voltage is increased progressively starting from the threshold voltage for the activation of discharge activity, indicating that the rate of total power transferred in the DUT may be tuned using the amplitude of the applied voltage. External confirmation of a significant power transfer taking place in these conditions is obtained through the observation of damage inflicted on the DUT after a period of sustained discharge activity at low pressure.

Journal of Physics Conference SeriesVol. 2952(1)
Montefiore Hospital (GB)
Openalex Percentile: Top 98%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.