Control of Voltage-Source Series-Resonant Inverters With Extended Topology Using Pulse-Density and Pulse-Frequency Modulations

This paper presents a control strategy for series resonant voltage-source inverters with extended topology using both pulse-density modulation (PDM) and pulse-frequency modulation (PFM). PDM regulates the output current for pulse density values from 0.5 to 1, while PFM applies for values below 0.5. The features of this strategy are: 1) when the half-bridge part of the extended inverter is utilized under PDM, the injection interval duration is a multiple of the half-cycle of the inverter output period, enabling the solution of the voltage imbalance problem; 2) using PFM completely avoids amplitude fluctuations in the output current, thereby inherently eliminating the voltage imbalance problem. Simulation results confirm the effectiveness of the proposed control strategy.

Authors

Institutions

Publication Details

Published
2024-10-07
DOI
https://doi.org/10.1109/khpiweek61434.2024.10877983
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Control of Voltage-Source Series-Resonant Inverters With Extended Topology Using Pulse-Density and Pulse-Frequency Modulations

Pavlo Herasymenko, Saurabh Mehta
Advanced DC-DC Converters
article

Control of Voltage-Source Series-Resonant Inverters With Extended Topology Using Pulse-Density and Pulse-Frequency Modulations

Pavlo Herasymenko, Saurabh Mehta
article en

Abstract

This paper presents a control strategy for series resonant voltage-source inverters with extended topology using both pulse-density modulation (PDM) and pulse-frequency modulation (PFM). PDM regulates the output current for pulse density values from 0.5 to 1, while PFM applies for values below 0.5. The features of this strategy are: 1) when the half-bridge part of the extended inverter is utilized under PDM, the injection interval duration is a multiple of the half-cycle of the inverter output period, enabling the solution of the voltage imbalance problem; 2) using PFM completely avoids amplitude fluctuations in the output current, thereby inherently eliminating the voltage imbalance problem. Simulation results confirm the effectiveness of the proposed control strategy.

Institute of Electrodynamics (UA)
Affordable and clean energy
Openalex Percentile: Top 75%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.