Effect of Lithium Ion on Electrochemiluminescent Response of Sensors Based on Langmuir-Blodgett Films with Polycyclic Organic Phosphors

This work reports the results of electrolysis of an aqueous solution containing lithium perchlorate as a supporting electrolyte and tripropylamine (TPrA) electrochemiluminescence (ECL) as a coreactant on ITO electrodes modified with a 9.,10-diphenylanthracene (DPA) phosphor in a polymethylmethacrylate (PMMA) matrix deposited by the Langmuir-Blodgett method. The results show that lithium perchlorate solution gives a background ECL signal in the absence of coreactant, and when TPrA is added, the shape and appearance of the ECL emission change., whereas TPrA/DPA system gives no ECL emission. Changing lithium perchlorate to sodium perchlorate leads to the disappearance of ECL, and purification with an organic solvent of lithium perchlorate does not affect the light emission, indicating the specific behavior of the lithium-ion during electrolysis. Special attention is also paid to the procedure of cleaning ITO substrates before film deposition and after its use with chloroform vapor in a distillation setup.

Authors

Institutions

Publication Details

Published
2024-10-07
DOI
https://doi.org/10.1109/khpiweek61434.2024.10878007
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Lithium Ion on Electrochemiluminescent Response of Sensors Based on Langmuir-Blodgett Films with Polycyclic Organic Phosphors

Mykola I. Slipchenko, Dmytro Snizhko, Danylo Martynov, Yuriy Zholudov
Analytical Chemistry and Sensors
article

Effect of Lithium Ion on Electrochemiluminescent Response of Sensors Based on Langmuir-Blodgett Films with Polycyclic Organic Phosphors

Mykola I. Slipchenko, Dmytro Snizhko, Danylo Martynov, Yuriy Zholudov
article en

Abstract

This work reports the results of electrolysis of an aqueous solution containing lithium perchlorate as a supporting electrolyte and tripropylamine (TPrA) electrochemiluminescence (ECL) as a coreactant on ITO electrodes modified with a 9.,10-diphenylanthracene (DPA) phosphor in a polymethylmethacrylate (PMMA) matrix deposited by the Langmuir-Blodgett method. The results show that lithium perchlorate solution gives a background ECL signal in the absence of coreactant, and when TPrA is added, the shape and appearance of the ECL emission change., whereas TPrA/DPA system gives no ECL emission. Changing lithium perchlorate to sodium perchlorate leads to the disappearance of ECL, and purification with an organic solvent of lithium perchlorate does not affect the light emission, indicating the specific behavior of the lithium-ion during electrolysis. Special attention is also paid to the procedure of cleaning ITO substrates before film deposition and after its use with chloroform vapor in a distillation setup.

Kharkiv National University of Radio Electronics (UA), National Academy of Sciences of Ukraine (UA), Institute for Scintillation Materials (UA)
National Research Foundation of Ukraine, Ministry of Education and Science of Ukraine
Openalex Percentile: Top 71%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.