Effect of Terminal Fault on Transient Voltage Under Different Wind and Fire Ratio

In order to effectively solve the large-scale wind power transmission alone power absorption and instability, to counter China’s energy and load consumption present reverse distribution. The large-scale wind-fire power is delivered through UHVDC, but because of the long distance and the random intermittency of new energy, the possibility of transmission line failure is greatly increased. In this paper, a model of UHVDC delivery of wind-fire bundling is established, the effect of short circuit on commutation failure and the formation mechanism of transient voltage characteristics of the AC system at the receiving end are described, and the effects of different wind and fire ratio delivery scenarios are analyzed, the effect of different types of short circuit at the receiving end on the transient voltage. The simulation results show that the single-phase-to-ground fault will do more harm to the stable operation and fault recovery of power grid with the increase of the proportion of outside wind power, it is beneficial to new energy absorption and stable operation of the system.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/epee63731.2024.10875327
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Terminal Fault on Transient Voltage Under Different Wind and Fire Ratio

Yutong Zhou, Ruihua Xia, Qingshan Li, Tianze Liu et al.
Lightning and Electromagnetic Phenomena
article

Effect of Terminal Fault on Transient Voltage Under Different Wind and Fire Ratio

Yutong Zhou, Ruihua Xia, Qingshan Li, Tianze Liu, Yongqiang Zhu
article en

Abstract

In order to effectively solve the large-scale wind power transmission alone power absorption and instability, to counter China’s energy and load consumption present reverse distribution. The large-scale wind-fire power is delivered through UHVDC, but because of the long distance and the random intermittency of new energy, the possibility of transmission line failure is greatly increased. In this paper, a model of UHVDC delivery of wind-fire bundling is established, the effect of short circuit on commutation failure and the formation mechanism of transient voltage characteristics of the AC system at the receiving end are described, and the effects of different wind and fire ratio delivery scenarios are analyzed, the effect of different types of short circuit at the receiving end on the transient voltage. The simulation results show that the single-phase-to-ground fault will do more harm to the stable operation and fault recovery of power grid with the increase of the proportion of outside wind power, it is beneficial to new energy absorption and stable operation of the system.

North China Electric Power University (CN)
Affordable and clean energy
Openalex Percentile: Top 80%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Terminal Fault on Transient Voltage Under Different Wind and Fire Ratio — Yutong Zhou, Ruihua Xia, et al. · (2024) | TGRS Research Map | TGRS