Radiation shielding analysis of fuel transfer channel for HPR1000
Based on the CNP1000 and ACP1000 design experience and operation feedback from national NPPs, the radiation protection and shielding design of fuel transfer channel for HPR1000 has been developed into an optimized one. The radiation protection and shielding design of HPR1000 fuel transfer channel has been proven to meet the safety requirements and criteria through detailed and accurate analysis and comparison, and have been demonstrated the validity, rationality and reliability of labyrinth radiation shielding design. Furthermore, the radiation protection and shielding design of fuel transfer channel for HPR1000 has advantage over which in international Generation III NPPs. (i.e., AP1000 and EPR).
Authors
- Yingnan Tian
- Puzhong Zhang
- Siyang Xie
- Aijun Mi
- Gang Li (ORCID: https://orcid.org/0000-0003-0249-5230)
- Song Liu
- Jingyi Shen (ORCID: https://orcid.org/0009-0009-6223-069X)
- Yawei Mao (ORCID: https://orcid.org/0000-0002-7387-1726)
Institutions
- China General Nuclear Power Corporation (China) (CN)
Publication Details
- Published
- 2024-09-20
- DOI
- https://doi.org/10.1109/epee63731.2024.10875357
- Primary Topic
- Nuclear reactor physics and engineering
- Type
- article
- Field-Weighted Citation Impact
- 0.00