Research and Design of Corrugated Vertical Switch Oil Tank

With the development of the economy and the improvement of living standards, the continuous increase in load demands higher stability and safety from power grid equipment. However, traditional oil tanks have design limitations that prevent effective isolation from air, leading to moisture degradation of the insulating oil and abnormal oil levels due to temperature changes. To address these issues, this study designed a fully sealed corrugated vertical switch oil tank. The new oil tank features a fully sealed design, effectively preventing direct contact between the transformer oil and air, thereby reducing the risk of oil oxidation and moisture contamination. The tank’s structure also incorporates a vertical corrugated design, providing sufficient space for oil level compensation under varying temperatures, thereby enhancing operational safety. Additionally, this study developed a digital monitoring technology that allows real-time monitoring of oil quality and other critical operating parameters. This highly automated monitoring system improves data accuracy and timeliness, enabling more precise assessments of equipment conditions and data-driven decision-making.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/epee63731.2024.10875328
Primary Topic
Advanced Algorithms and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research and Design of Corrugated Vertical Switch Oil Tank

Jianfu Ma, Zhi‐Yong Wu, J. L. Hou, Peng Guo et al.
1 links
Advanced Algorithms and Applications
article

Research and Design of Corrugated Vertical Switch Oil Tank

Jianfu Ma, Zhi‐Yong Wu, J. L. Hou, Peng Guo, Qian Liu, F.X. Li, Dongfang Wang, Li Hu, Xin Ma, Fuqiang Hei
article en

Abstract

With the development of the economy and the improvement of living standards, the continuous increase in load demands higher stability and safety from power grid equipment. However, traditional oil tanks have design limitations that prevent effective isolation from air, leading to moisture degradation of the insulating oil and abnormal oil levels due to temperature changes. To address these issues, this study designed a fully sealed corrugated vertical switch oil tank. The new oil tank features a fully sealed design, effectively preventing direct contact between the transformer oil and air, thereby reducing the risk of oil oxidation and moisture contamination. The tank’s structure also incorporates a vertical corrugated design, providing sufficient space for oil level compensation under varying temperatures, thereby enhancing operational safety. Additionally, this study developed a digital monitoring technology that allows real-time monitoring of oil quality and other critical operating parameters. This highly automated monitoring system improves data accuracy and timeliness, enabling more precise assessments of equipment conditions and data-driven decision-making.

Shanghai Electric (China) (CN)
State Grid Corporation of China
Openalex Percentile: Top 66%
Advanced Algorithms and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research and Design of Corrugated Vertical Switch Oil Tank — Jianfu Ma, Zhi‐Yong Wu, et al. · (2024) | TGRS Research Map | TGRS