Open-Pit Railway Transport Traction Complex Power Consumption Mode Modelling

This paper is a study of the power consumption modes of an open pit rail transport traction complex. To study the power consumption modes of the rail transport complex, a model of a traction transformer substation that supplies part of the traction network was developed in a visual programming environment, and the operation of a traction network consisting of four locomotives with different control angles of the rectifier of each locomotive was Simulation. Using the IEEE 1459–2010 standard, the order of distribution of power components for a three-phase circuit is calculated. The obtained results indicate a clear asymmetry of voltage and current caused by the peculiarities of the AC contact network. The current distortion power, under all modes, on the primary and secondary windings has a slight difference, and the voltage distortion power on the side of the contact network significantly exceeds this indicator on the source side.

Authors

Institutions

Publication Details

Published
2024-10-07
DOI
https://doi.org/10.1109/khpiweek61434.2024.10878101
Primary Topic
Railway Systems and Energy Efficiency
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Open-Pit Railway Transport Traction Complex Power Consumption Mode Modelling

Maxim Oliynichenko, Maksim Bezzub, Olexii Bialobrzheskyi
Railway Systems and Energy Efficiency
article

Open-Pit Railway Transport Traction Complex Power Consumption Mode Modelling

Maxim Oliynichenko, Maksim Bezzub, Olexii Bialobrzheskyi
article en

Abstract

This paper is a study of the power consumption modes of an open pit rail transport traction complex. To study the power consumption modes of the rail transport complex, a model of a traction transformer substation that supplies part of the traction network was developed in a visual programming environment, and the operation of a traction network consisting of four locomotives with different control angles of the rectifier of each locomotive was Simulation. Using the IEEE 1459–2010 standard, the order of distribution of power components for a three-phase circuit is calculated. The obtained results indicate a clear asymmetry of voltage and current caused by the peculiarities of the AC contact network. The current distortion power, under all modes, on the primary and secondary windings has a slight difference, and the voltage distortion power on the side of the contact network significantly exceeds this indicator on the source side.

Kremenchuk Mykhailo Ostrohradskyi National University (UA)
Affordable and clean energy
Openalex Percentile: Top 60%
Railway Systems and Energy Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.