Analysis of Temperature and Relative Humidity Distributions in a Dental Treatment Room at a Government Health Clinic in Malaysia

This study investigates the vertical distribution of temperature and relative humidity within dental treatment rooms at a Government Type 3 Health Clinic in Gial Perlis, Malaysia, addressing a significant gap in the literature regarding environmental conditions in dental healthcare settings. Precise measurements were conducted at four specific heights 0.3 m, 1.0 m, 1.7 m, and 2.7 m utilizing calibrated digital thermometers with hygrometers to capture accurate environmental data. The collected data were analysed using Analysis of Variance (ANOVA) to assess the significance of variations across these levels. Results revealed statistically significant differences in both temperature and relative humidity (p < 0.05). At the uppermost level (2.7 m), the highest mean temperature of 22.1°C and a mean relative humidity of 68.2% were recorded, while the lowest level (0.3 m) exhibited the lowest mean temperature of 20.9°C and the highest mean relative humidity of 73.8%. Temperatures at the patient level (1.0 m and 1.7 m) averaged between 21.0 °C and 21.6°C, which is slightly below the optimal comfort range of 22°C to 26°C. These vertical gradients indicate that the existing HVAC systems may not be effectively regulating indoor conditions, potentially impacting patient comfort, the performance of temperature-sensitive dental materials, and the effectiveness of infection control measures due to altered aerosol behaviour. The findings underscore the necessity of optimizing HVAC designs to achieve uniform temperature and humidity distributions within dental treatment rooms. This research provides valuable insights for healthcare professionals and policymakers, emphasizing the importance of tailored environmental management strategies to enhance patient comfort, procedural outcomes, and safety in dental healthcare settings.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Published
2025-02-10
DOI
https://doi.org/10.37934/arfmts.127.1.119
Primary Topic
Dental Research and COVID-19
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Temperature and Relative Humidity Distributions in a Dental Treatment Room at a Government Health Clinic in Malaysia

Muhd Nur Rahman Yahya, Z M Razlan, A B Shahriman, Naoki Maruyama et al.
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Dental Research and COVID-19
article

Analysis of Temperature and Relative Humidity Distributions in a Dental Treatment Room at a Government Health Clinic in Malaysia

Muhd Nur Rahman Yahya, Z M Razlan, A B Shahriman, Naoki Maruyama, Eswanto Eswanto, Mohamad Nazrin Yahaya, Anas Abdul Rahman, Muhammad Faiz Hilmi Rani
article en

Abstract

This study investigates the vertical distribution of temperature and relative humidity within dental treatment rooms at a Government Type 3 Health Clinic in Gial Perlis, Malaysia, addressing a significant gap in the literature regarding environmental conditions in dental healthcare settings. Precise measurements were conducted at four specific heights 0.3 m, 1.0 m, 1.7 m, and 2.7 m utilizing calibrated digital thermometers with hygrometers to capture accurate environmental data. The collected data were analysed using Analysis of Variance (ANOVA) to assess the significance of variations across these levels. Results revealed statistically significant differences in both temperature and relative humidity (p < 0.05). At the uppermost level (2.7 m), the highest mean temperature of 22.1°C and a mean relative humidity of 68.2% were recorded, while the lowest level (0.3 m) exhibited the lowest mean temperature of 20.9°C and the highest mean relative humidity of 73.8%. Temperatures at the patient level (1.0 m and 1.7 m) averaged between 21.0 °C and 21.6°C, which is slightly below the optimal comfort range of 22°C to 26°C. These vertical gradients indicate that the existing HVAC systems may not be effectively regulating indoor conditions, potentially impacting patient comfort, the performance of temperature-sensitive dental materials, and the effectiveness of infection control measures due to altered aerosol behaviour. The findings underscore the necessity of optimizing HVAC designs to achieve uniform temperature and humidity distributions within dental treatment rooms. This research provides valuable insights for healthcare professionals and policymakers, emphasizing the importance of tailored environmental management strategies to enhance patient comfort, procedural outcomes, and safety in dental healthcare settings.

Journal of Advanced Research in Fluid Mechanics and Thermal SciencesVol. 127(1)
Mie University (JP), State University of Medan (ID), University of Technology Malaysia (MY), Universiti Malaysia Perlis (MY)
Universiti Malaysia Perlis
Openalex Percentile: Top 95%
Dental Research and COVID-19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.