Application of Artificial Neural Networks for Accurate Non-Invasive In Vivo Glucose Determination with Microwave Sensor

Microwave sensors offer precise and non-invasive real-time glucose monitoring for diabetes management. This study explores the integration of microwave sensors and artificial neural networks (ANNs) for non-invasive glucose determination. The setup involves a Vector Network Analyser across a frequency range of 0.015 GHz to 8 GHz. Dielectric measurements for in vivo blood glucose levels were conducted with an open-ended coaxial sensor, capturing data from the pulse, thumb, and finger, and compared against invasive glucose meters. The Levenberg-Marquardt algorithm is employed to train ANNs, enhancing predictive accuracy. Results indicate the optimal neural network configuration varies per dataset, with the pulse dataset achieving the highest regression (R) value of 0.9706. Sensitivity analysis highlights the significance of 'Frequency' and 'Dielectric Constant' as key predictors. This study validates the feasibility of microwave sensors and ANNs for accurate, non-invasive in vivo glucose monitoring, advancing diabetes management.

Authors

Institutions

Publication Details

Published
2024-12-21
DOI
https://doi.org/10.1109/apace62360.2024.10877403
Citations
1
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.24

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Artificial Neural Networks for Accurate Non-Invasive In Vivo Glucose Determination with Microwave Sensor

Ee Meng Cheng, Kok Yeow You, Yong-Hong Lee, Gobi Vetharatnam et al.
1 citations
Spectroscopy and Chemometric Analyses
0.24
article

Application of Artificial Neural Networks for Accurate Non-Invasive In Vivo Glucose Determination with Microwave Sensor

Ee Meng Cheng, Kok Yeow You, Yong-Hong Lee, Gobi Vetharatnam, Eng-Hock Lim, Kyung‐Sub Lee
article en
1 citations

Abstract

Microwave sensors offer precise and non-invasive real-time glucose monitoring for diabetes management. This study explores the integration of microwave sensors and artificial neural networks (ANNs) for non-invasive glucose determination. The setup involves a Vector Network Analyser across a frequency range of 0.015 GHz to 8 GHz. Dielectric measurements for in vivo blood glucose levels were conducted with an open-ended coaxial sensor, capturing data from the pulse, thumb, and finger, and compared against invasive glucose meters. The Levenberg-Marquardt algorithm is employed to train ANNs, enhancing predictive accuracy. Results indicate the optimal neural network configuration varies per dataset, with the pulse dataset achieving the highest regression (R) value of 0.9706. Sensitivity analysis highlights the significance of 'Frequency' and 'Dielectric Constant' as key predictors. This study validates the feasibility of microwave sensors and ANNs for accurate, non-invasive in vivo glucose monitoring, advancing diabetes management.

University of Technology Malaysia (MY), Universiti Malaysia Perlis (MY), Universiti Tunku Abdul Rahman (MY)
Universiti Tunku Abdul Rahman
Zero hunger
Openalex Percentile: Top 48%
Spectroscopy and Chemometric Analyses
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.