Simplified Multi-Channel Calibration for Microwave Imaging Systems

This work proposes and validates a simplified n-channel calibration for microwave imaging systems that reduces the complexity of a standard full-port calibration from a minimum of 4n − 1 measurements to 4(2) 1 ones, respectively. The method consists of a joined 2-port −standard calibration with a multi-port extrapolation. It compensates for systematic errors and mitigates the effects of losses and phase shifting caused by the multiplexing stage of a microwave imaging system. The conditioning and limitations of the technique are studied, including the switching matrix’s dynamic range, insertion loss, and the error path extrapolation analysis. Finally, the calibration is validated by employing a brain stroke monitoring system using either an electromechanical switching matrix or a solid-state-based one, and repeatability and stability tests that demonstrate the calibration’s effectiveness and robustness are performed.

Authors

Institutions

Publication Details

Published
2024-12-01
DOI
https://doi.org/10.1109/lacap63752.2024.10876286
Primary Topic
Microwave Imaging and Scattering Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simplified Multi-Channel Calibration for Microwave Imaging Systems

J. A. Tobón Vasquez, Lorenzo Crocco, Rosa Scapaticci, Francesca Vipiana et al.
Microwave Imaging and Scattering Analysis
article

Simplified Multi-Channel Calibration for Microwave Imaging Systems

J. A. Tobón Vasquez, Lorenzo Crocco, Rosa Scapaticci, Francesca Vipiana, D. O. Rodriguez-Duarte, M. Gugliermino
article en

Abstract

This work proposes and validates a simplified n-channel calibration for microwave imaging systems that reduces the complexity of a standard full-port calibration from a minimum of 4n − 1 measurements to 4(2) 1 ones, respectively. The method consists of a joined 2-port −standard calibration with a multi-port extrapolation. It compensates for systematic errors and mitigates the effects of losses and phase shifting caused by the multiplexing stage of a microwave imaging system. The conditioning and limitations of the technique are studied, including the switching matrix’s dynamic range, insertion loss, and the error path extrapolation analysis. Finally, the calibration is validated by employing a brain stroke monitoring system using either an electromechanical switching matrix or a solid-state-based one, and repeatability and stability tests that demonstrate the calibration’s effectiveness and robustness are performed.

Politecnico di Torino (IT), Istituto per il Rilevamento Elettromagnetico dell'Ambiente (IT), National Research Council (IT)
Interreg
Affordable and clean energy
Openalex Percentile: Top 76%
Microwave Imaging and Scattering Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simplified Multi-Channel Calibration for Microwave Imaging Systems — J. A. Tobón Vasquez, Lorenzo Crocco, et al. · (2024) | TGRS Research Map | TGRS