Fault Location for Series Compensated Lines Eliminating Parameters as a Setting

Unlike protection applications, precise fault locator requires accurate line parameters which are not constant over the time as a result of aging and environmental impact on conductors. Traditional fault location approaches for series compensated lines are dependent on the prior knowledge of line electrical parameters, percentage and type of compensation. However, nonlinear characteristics of Metal Oxide Varistor (MOV) during fault makes the task of fault location more complex. In order to address these, a setting free fault location methodology for series compensated lines using synchronized data is proposed which is independent of MOV characteristics. The fault location algorithm is phasor-based and parameters are estimated using Dommel’s time domain equations. Estimation of parameters requires computation of propagation constant which is obtained using first two travelling wave peak arrival times of arial mode component of both end fault currents. Wavelet transform technique is used to extract the travelling waves. The proposed method is independent of the percentage, type, location of the compensation and MOV characteristics. The proposed method is verified using data simulated in PSCAD/EMTDC tools. The proposed method is tested for different fault scenarios and performance is found to be accurate.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/isgtasia61245.2024.10876364
Citations
1
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Location for Series Compensated Lines Eliminating Parameters as a Setting

N. V. Srikanth, O. D. Naidu, Penta Rithisha
1 citations
Power Systems Fault Detection
0.33
article

Fault Location for Series Compensated Lines Eliminating Parameters as a Setting

N. V. Srikanth, O. D. Naidu, Penta Rithisha
article en
1 citations

Abstract

Unlike protection applications, precise fault locator requires accurate line parameters which are not constant over the time as a result of aging and environmental impact on conductors. Traditional fault location approaches for series compensated lines are dependent on the prior knowledge of line electrical parameters, percentage and type of compensation. However, nonlinear characteristics of Metal Oxide Varistor (MOV) during fault makes the task of fault location more complex. In order to address these, a setting free fault location methodology for series compensated lines using synchronized data is proposed which is independent of MOV characteristics. The fault location algorithm is phasor-based and parameters are estimated using Dommel’s time domain equations. Estimation of parameters requires computation of propagation constant which is obtained using first two travelling wave peak arrival times of arial mode component of both end fault currents. Wavelet transform technique is used to extract the travelling waves. The proposed method is independent of the percentage, type, location of the compensation and MOV characteristics. The proposed method is verified using data simulated in PSCAD/EMTDC tools. The proposed method is tested for different fault scenarios and performance is found to be accurate.

National Institute of Technology Warangal (IN), Renewable Energy Corporation of India (IN)
Climate action
Openalex Percentile: Top 36%
Power Systems Fault Detection
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.