Low-Frequency and Small-Signal Aggregate Load Model Estimation using Ambient Measurements

Load modeling is a challenging problem even today due to the diverse, time-varying and complex nature of loads. The paper investigates the use of the well-known ARMAX method for obtaining a low-frequency, small-signal, aggregate, and dynamic load model using ambient measurements. A realistic model of a 16-machine system driven by random low-level load switching is used to analyze the accuracy of this method. The paper highlights the limitations of the method and the conditions under which it is suitable for identifying the load models. It is shown that the influence of the local load switching noise on the local bus voltage and frequency is a critical factor for accurate estimation. The method works well only if this feedback or the level of local load switching noise is low. An indicator to flag the estimates that are likely to be unreliable is proposed and validated.

Authors

Institutions

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/isgtasia61245.2024.10876325
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Frequency and Small-Signal Aggregate Load Model Estimation using Ambient Measurements

Malay B. Mukherjee, A. M. Kulkarni
Structural Health Monitoring Techniques
article

Low-Frequency and Small-Signal Aggregate Load Model Estimation using Ambient Measurements

Malay B. Mukherjee, A. M. Kulkarni
article en

Abstract

Load modeling is a challenging problem even today due to the diverse, time-varying and complex nature of loads. The paper investigates the use of the well-known ARMAX method for obtaining a low-frequency, small-signal, aggregate, and dynamic load model using ambient measurements. A realistic model of a 16-machine system driven by random low-level load switching is used to analyze the accuracy of this method. The paper highlights the limitations of the method and the conditions under which it is suitable for identifying the load models. It is shown that the influence of the local load switching noise on the local bus voltage and frequency is a critical factor for accurate estimation. The method works well only if this feedback or the level of local load switching noise is low. An indicator to flag the estimates that are likely to be unreliable is proposed and validated.

Indian Institute of Technology Bombay (IN)
Climate action
Openalex Percentile: Top 69%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low-Frequency and Small-Signal Aggregate Load Model Estimation using Ambient Measurements — Malay B. Mukherjee, A. M. Kulkarni · (2024) | TGRS Research Map | TGRS