Simulation Analysis of Oil Velocity Features under Internal Arc Discharge Conditions in Transformer

This paper presents a simulation analysis of oil velocity characteristics under internal arc discharge conditions in transformers, supported by experimental validation. When an arc discharge occurs, the insulating oil at the fault point vaporizes, forming high-pressure bubbles that induce significant pressure differences, causing fluid flow. The study models this effect by calculating arc energy, establishing the relationship between fault energy and gas production, and simulating the resulting pressure and flow velocity changes. A three-dimensional model of a 110 kV oil-immersed transformer was developed to simulate flow velocity distribution during are discharges. The simulation results were verified through experiments, which involved measuring oil flow velocities at four monitoring points. The experimental data closely matched the simulation predictions, confirming the reliability of the model. This work demonstrates the potential for using oil flow velocity changes to detect transformer faults and provides insights into transformer fault diagnosis.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/epee63731.2024.10875490
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation Analysis of Oil Velocity Features under Internal Arc Discharge Conditions in Transformer

Bo Qi, Hao Ge, Linjie Zhao, Chunjia Gao et al.
Engineering Diagnostics and Reliability
article

Simulation Analysis of Oil Velocity Features under Internal Arc Discharge Conditions in Transformer

Bo Qi, Hao Ge, Linjie Zhao, Chunjia Gao, Cui Yan, Shuai Zhang, Wei Zhang, Mingcheng Hua, Wenyuan Shangguan, Desheng Chu
article en

Abstract

This paper presents a simulation analysis of oil velocity characteristics under internal arc discharge conditions in transformers, supported by experimental validation. When an arc discharge occurs, the insulating oil at the fault point vaporizes, forming high-pressure bubbles that induce significant pressure differences, causing fluid flow. The study models this effect by calculating arc energy, establishing the relationship between fault energy and gas production, and simulating the resulting pressure and flow velocity changes. A three-dimensional model of a 110 kV oil-immersed transformer was developed to simulate flow velocity distribution during are discharges. The simulation results were verified through experiments, which involved measuring oil flow velocities at four monitoring points. The experimental data closely matched the simulation predictions, confirming the reliability of the model. This work demonstrates the potential for using oil flow velocity changes to detect transformer faults and provides insights into transformer fault diagnosis.

North China Electric Power University (CN), State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, China Southern Power Grid (China) (CN)
Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 70%
Engineering Diagnostics and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation Analysis of Oil Velocity Features under Internal Arc Discharge Conditions in Transformer — Bo Qi, Hao Ge, et al. · (2024) | TGRS Research Map | TGRS