Model based Protection for Export Cables Connecting Off-shore Wind Farms to the Grid

Long export cables help in transfer of the electricity generated from offshore wind farms. Installation and maintenance of such cables are expensive. Reliable protection system which safeguards them during faults is essential. Limited fault currents, unique and non-homogeneous fault response from the wind farm converters, multiple inhomogeneous cable sections, etc. may render traditional protection principles such as distance and differential inadequate. This paper explores the application of an alternate principle, namely model based protection (MBP). It uses the model and measurements related to the export cable in a state estimation framework to detect faults. In addition to detection of faults, MBP can also help identify faulted phases and/or faulted cable section which can be beneficial for other fault management applications. MBP is comprehensive and can potentially minimize the need for complementary protection relays, thereby reducing the overall footprint of protection and control system in offshore platforms. Case studies are done using PSCAD/EMTDC simulations of a typical 220 kV, 160 km long export cable network connecting an offshore wind farm to the main grid.

Authors

Publication Details

Published
2024-11-10
DOI
https://doi.org/10.1109/isgtasia61245.2024.10876237
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Model based Protection for Export Cables Connecting Off-shore Wind Farms to the Grid

O. D. Naidu, Vedanta Pradhan
Islanding Detection in Power Systems
article

Model based Protection for Export Cables Connecting Off-shore Wind Farms to the Grid

O. D. Naidu, Vedanta Pradhan
article en

Abstract

Long export cables help in transfer of the electricity generated from offshore wind farms. Installation and maintenance of such cables are expensive. Reliable protection system which safeguards them during faults is essential. Limited fault currents, unique and non-homogeneous fault response from the wind farm converters, multiple inhomogeneous cable sections, etc. may render traditional protection principles such as distance and differential inadequate. This paper explores the application of an alternate principle, namely model based protection (MBP). It uses the model and measurements related to the export cable in a state estimation framework to detect faults. In addition to detection of faults, MBP can also help identify faulted phases and/or faulted cable section which can be beneficial for other fault management applications. MBP is comprehensive and can potentially minimize the need for complementary protection relays, thereby reducing the overall footprint of protection and control system in offshore platforms. Case studies are done using PSCAD/EMTDC simulations of a typical 220 kV, 160 km long export cable network connecting an offshore wind farm to the main grid.

Affordable and clean energy
Openalex Percentile: Top 75%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Model based Protection for Export Cables Connecting Off-shore Wind Farms to the Grid — O. D. Naidu, Vedanta Pradhan · (2024) | TGRS Research Map | TGRS