An SVM-Based Anomaly Detection Method for Power System Security Analysis Using Particle Swarm Optimization and t-SNE for High-Dimensional Data Classification

Research on the detection and identification of anomalies in electric power systems is crucial for ensuring their secure and stable operation. Anomaly detection models based on Support Vector Machines (SVMs) effectively process high-dimensional data while maintaining strong generalization capabilities. However, the performance of SVMs significantly depends on the choice of parameters, where improper parameter settings can lead to overfitting or underfitting, consequently decreasing the accuracy of anomaly detection. Furthermore, the dimensions of anomaly data in electric power systems are often unknown, making it difficult for existing methods to maintain a high precision in multidimensional data detection, and the segmentation of such data lacks intuitive display. In response, this article proposes an improved SVM model for electric power system anomaly detection, enhanced by parameter optimization algorithms, alongside a method for nonlinear dimension reduction and visualization using t-Distributed Stochastic Neighbor Embedding (t-SNE). Initially, traditional SVM parameters are optimized using the following four algorithms: Grid Search (GS), Particle Swarm Optimization (PSO), Genetic Algorithms (GAs), and Artificial Bee Colony (ABC) algorithms, in order to establish the optimized SVM model for electric power system anomaly detection. Finally, the effectiveness of the proposed method is verified through simulations. The simulation results indicate that, in the IEEE-14 node system case study, the accuracy for normal data reaches 97.58%, the accuracy for load step change detection reaches 99.52%, the accuracy for bad data detection reaches 99.92%, and the accuracy under fault conditions reaches 100%.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-02-15
DOI
https://doi.org/10.3390/pr13020549
Citations
7
Primary Topic
Network Security and Intrusion Detection
Type
article
Field-Weighted Citation Impact
10.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An SVM-Based Anomaly Detection Method for Power System Security Analysis Using Particle Swarm Optimization and t-SNE for High-Dimensional Data Classification

Jiongcheng Yan, Pengfei Zhai, Shuolin Zhang, Tao Ye et al.
7 citations
Processes
Network Security and Intrusion Detection
10.41
article

An SVM-Based Anomaly Detection Method for Power System Security Analysis Using Particle Swarm Optimization and t-SNE for High-Dimensional Data Classification

Jiongcheng Yan, Pengfei Zhai, Shuolin Zhang, Tao Ye, Enquan Niu
article en
7 citations

Abstract

Research on the detection and identification of anomalies in electric power systems is crucial for ensuring their secure and stable operation. Anomaly detection models based on Support Vector Machines (SVMs) effectively process high-dimensional data while maintaining strong generalization capabilities. However, the performance of SVMs significantly depends on the choice of parameters, where improper parameter settings can lead to overfitting or underfitting, consequently decreasing the accuracy of anomaly detection. Furthermore, the dimensions of anomaly data in electric power systems are often unknown, making it difficult for existing methods to maintain a high precision in multidimensional data detection, and the segmentation of such data lacks intuitive display. In response, this article proposes an improved SVM model for electric power system anomaly detection, enhanced by parameter optimization algorithms, alongside a method for nonlinear dimension reduction and visualization using t-Distributed Stochastic Neighbor Embedding (t-SNE). Initially, traditional SVM parameters are optimized using the following four algorithms: Grid Search (GS), Particle Swarm Optimization (PSO), Genetic Algorithms (GAs), and Artificial Bee Colony (ABC) algorithms, in order to establish the optimized SVM model for electric power system anomaly detection. Finally, the effectiveness of the proposed method is verified through simulations. The simulation results indicate that, in the IEEE-14 node system case study, the accuracy for normal data reaches 97.58%, the accuracy for load step change detection reaches 99.52%, the accuracy for bad data detection reaches 99.92%, and the accuracy under fault conditions reaches 100%.

ProcessesVol. 13(2)
Shandong University (CN), China Southern Power Grid (China) (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shandong Province
Openalex Percentile: Top 2%
Network Security and Intrusion Detection
10.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.