Development of a size-of-source effect measurement system for IR thermometers without water-cooling aperture

We have developed a size-of-source effect (SSE) measurement system for infrared (IR) thermometers. The SSE is a key factor for estimating calibration uncertainty, so SSE measurements are essential for calibrating IR thermometers. In general, SSE measurement systems have a water-cooling mechanism to keep their apertures at room temperature. However, such systems are complicated and costly. Here we propose a new SSE measurement system that can keep the aperture at room temperature even though it does not have a water-cooling mechanism. We performed SSE measurements on IR thermometers with the system and obtained satisfactory results. This paper discusses the system, the results, and the SSE measurement uncertainties.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2025-02-15
DOI
https://doi.org/10.1016/j.measen.2025.101834
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a size-of-source effect measurement system for IR thermometers without water-cooling aperture

Masato Koike
Measurement Sensors
Calibration and Measurement Techniques
article

Development of a size-of-source effect measurement system for IR thermometers without water-cooling aperture

Masato Koike
article en

Abstract

We have developed a size-of-source effect (SSE) measurement system for infrared (IR) thermometers. The SSE is a key factor for estimating calibration uncertainty, so SSE measurements are essential for calibrating IR thermometers. In general, SSE measurement systems have a water-cooling mechanism to keep their apertures at room temperature. However, such systems are complicated and costly. Here we propose a new SSE measurement system that can keep the aperture at room temperature even though it does not have a water-cooling mechanism. We performed SSE measurements on IR thermometers with the system and obtained satisfactory results. This paper discusses the system, the results, and the SSE measurement uncertainties.

Measurement SensorsVol. 38
Japan Electric Meters Inspection Corporation
Openalex Percentile: Top 96%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.