Method Development and Validation of Gramicidin, Neomycin and Triamcinolone Acetonide Related Substances and their Impurities Quantification through UPLC

Aim/Background To develop and validate a sensitive, accurate, simple, precise and cost-effective receptive and understandable method for concurrent evaluation of Gramicidin, Neomycin and Triamcinolone acetonide and their related contaminants via UPLC. Materials and Methods This method includes the separation using a chromatographic Phenyl column (50 mmx2.1 mm, 1.7 µm). A portable stage of 0.1% TEA (Tri-Ethylamine) and acetonitrile in gradient elution mode with 0.5mL/Temperature and minimum flow rate were employed. At 230 nm, UV observations were made. The limitations for Linearity, quantification and recoveries were discovered being within the allowable range. With UPLC, this method was successfully tested and ICH Q2 (R1) recommendations. Results Gramicidin, Neomycin and Triamcinolone acetonide retention times were observed at 9.315 min,3.979 min and 1.697 min respectively. A gradient elution of Triamcinolone acetonide, Neomycin and Gramicidin involves phenyl column that flows from 0.5 mL/min and the column internal temperature were held constant. Mobile phase % TEA likewise acetonitrile was utilised. UV monitoring was brought at 230 nm. Conclusion This study created an entirely new, straightforward, quick, affordable, sensitive and easily accessible UPLC method for the coincident determination of Triamcinolone acetonide, Neomycin and Gramicidin bulky and ointment dose form. This method has the benefits of being less expensive, assessible, reliable, sensitive and reproducible. Under conditions of oxidation, (Neutral, basic and acidic) hydrolysis, photolysis, thermal stress and medicines degradative activities were investigated. The medications were discovered to be solid underheat, unstable, hydrolysis under acid, alkaline and oxidative circumstances. The Final application of the UPLC method to the commercial formulations followed the ICH recommendations.

Authors

Institutions

Publication Details

Journal
International Journal of Pharmaceutical Investigation
Published
2025-02-12
DOI
https://doi.org/10.5530/ijpi.20251515
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method Development and Validation of Gramicidin, Neomycin and Triamcinolone Acetonide Related Substances and their Impurities Quantification through UPLC

Ibrahim Baje Syed, Madhavi Nannapaneni
International Journal of Pharmaceutical Investigation
Analytical Methods in Pharmaceuticals
article

Method Development and Validation of Gramicidin, Neomycin and Triamcinolone Acetonide Related Substances and their Impurities Quantification through UPLC

Ibrahim Baje Syed, Madhavi Nannapaneni
article en

Abstract

Aim/Background To develop and validate a sensitive, accurate, simple, precise and cost-effective receptive and understandable method for concurrent evaluation of Gramicidin, Neomycin and Triamcinolone acetonide and their related contaminants via UPLC. Materials and Methods This method includes the separation using a chromatographic Phenyl column (50 mmx2.1 mm, 1.7 µm). A portable stage of 0.1% TEA (Tri-Ethylamine) and acetonitrile in gradient elution mode with 0.5mL/Temperature and minimum flow rate were employed. At 230 nm, UV observations were made. The limitations for Linearity, quantification and recoveries were discovered being within the allowable range. With UPLC, this method was successfully tested and ICH Q2 (R1) recommendations. Results Gramicidin, Neomycin and Triamcinolone acetonide retention times were observed at 9.315 min,3.979 min and 1.697 min respectively. A gradient elution of Triamcinolone acetonide, Neomycin and Gramicidin involves phenyl column that flows from 0.5 mL/min and the column internal temperature were held constant. Mobile phase % TEA likewise acetonitrile was utilised. UV monitoring was brought at 230 nm. Conclusion This study created an entirely new, straightforward, quick, affordable, sensitive and easily accessible UPLC method for the coincident determination of Triamcinolone acetonide, Neomycin and Gramicidin bulky and ointment dose form. This method has the benefits of being less expensive, assessible, reliable, sensitive and reproducible. Under conditions of oxidation, (Neutral, basic and acidic) hydrolysis, photolysis, thermal stress and medicines degradative activities were investigated. The medications were discovered to be solid underheat, unstable, hydrolysis under acid, alkaline and oxidative circumstances. The Final application of the UPLC method to the commercial formulations followed the ICH recommendations.

International Journal of Pharmaceutical InvestigationVol. 15(2)
Alagappa University (IN), Cal Humanities (US)
Zero hunger
Openalex Percentile: Top 97%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.