Unlocking the potential of NH2-MIL-101 (Fe) nanoMOF for advanced electrochemical immunosensing in chronic wound diagnostics

In this work we take advantage, for the first time, of the porous and functional structure of a nanoscale metal organic framework (nanoMOF), specifically NH 2 -MIL-101 (Fe) nanoMOF, for its use as advantageous enzyme-carrier nanotag in immunoassays. In particular, the porous structure of the nanoMOF allows accommodating a high loading of enzyme molecules, which, in addition, are protected from degradation inside the pores providing a high stability. This property together with the ability of the nanoMOF to link antibodies through its functional groups make it a very robust and powerful label. Both the enhanced sensitivity, compared with the conventional use of enzyme-labelled antibodies, and the high long-term stability are demonstrated. Such nanotag also offers advantages related to ease of modification and cost effectiveness. The detection of myeloperoxidase (MPO), a key biomarker for chronic wound monitoring, is proposed to demonstrate the applicability of this approach. A sandwich-type immunoassay using magnetic beads (MBs)-based platforms and subsequent amperometric detection allows the determination of MPO in the clinical range (5 – 100 ng mL −1 ), with a limit of detection of 1.4 ng mL −1 , and good reproducibility (RSD (n = 10) = 7.1 %). The developed bio-strategy also exhibits high selectivity against potential interferents and a good stability of the nanotag for at least 2 months. Moreover, the developed method was successfully implemented to determine MPO in simulated chronic wound matrices, demonstrating its feasibility in a real scenario. • Novel tagging method for immunosensing exploiting a biomolecules decorated NH 2 -MIL-101 (Fe) nanoMOF. • Sandwich-type immunoassay for the amperometric determination of myeloperoxidase. • Sensitive (LOD of 1.4 ng mL −1 ) and selective determination of myeloperoxidase standards. • Threefold improvement in sensitivity compared to conventional sandwich immunoassay formats. • Successful analysis in simulated chronic wound matrices.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-02-16
DOI
https://doi.org/10.1016/j.snb.2025.137460
Citations
1
Primary Topic
Anodic Oxide Films and Nanostructures
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Unlocking the potential of NH2-MIL-101 (Fe) nanoMOF for advanced electrochemical immunosensing in chronic wound diagnostics

Víctor Pérez‐Ginés, José M. Pingarrón, Alfredo de la Escosura‐Muñiz, Susana Campuzano et al.
1 citations
Sensors and Actuators B Chemical
Anodic Oxide Films and Nanostructures
0.52
article

Unlocking the potential of NH2-MIL-101 (Fe) nanoMOF for advanced electrochemical immunosensing in chronic wound diagnostics

Víctor Pérez‐Ginés, José M. Pingarrón, Alfredo de la Escosura‐Muñiz, Susana Campuzano, Francisco J. Garcı́a Alonso, Rebeca M. Torrente‐Rodríguez, David Valero‐Calvo, Marı́a Pedrero
article en
1 citations

Abstract

In this work we take advantage, for the first time, of the porous and functional structure of a nanoscale metal organic framework (nanoMOF), specifically NH 2 -MIL-101 (Fe) nanoMOF, for its use as advantageous enzyme-carrier nanotag in immunoassays. In particular, the porous structure of the nanoMOF allows accommodating a high loading of enzyme molecules, which, in addition, are protected from degradation inside the pores providing a high stability. This property together with the ability of the nanoMOF to link antibodies through its functional groups make it a very robust and powerful label. Both the enhanced sensitivity, compared with the conventional use of enzyme-labelled antibodies, and the high long-term stability are demonstrated. Such nanotag also offers advantages related to ease of modification and cost effectiveness. The detection of myeloperoxidase (MPO), a key biomarker for chronic wound monitoring, is proposed to demonstrate the applicability of this approach. A sandwich-type immunoassay using magnetic beads (MBs)-based platforms and subsequent amperometric detection allows the determination of MPO in the clinical range (5 – 100 ng mL −1 ), with a limit of detection of 1.4 ng mL −1 , and good reproducibility (RSD (n = 10) = 7.1 %). The developed bio-strategy also exhibits high selectivity against potential interferents and a good stability of the nanotag for at least 2 months. Moreover, the developed method was successfully implemented to determine MPO in simulated chronic wound matrices, demonstrating its feasibility in a real scenario. • Novel tagging method for immunosensing exploiting a biomolecules decorated NH 2 -MIL-101 (Fe) nanoMOF. • Sandwich-type immunoassay for the amperometric determination of myeloperoxidase. • Sensitive (LOD of 1.4 ng mL −1 ) and selective determination of myeloperoxidase standards. • Threefold improvement in sensitivity compared to conventional sandwich immunoassay formats. • Successful analysis in simulated chronic wound matrices.

Sensors and Actuators B ChemicalVol. 432
Universidad Complutense de Madrid (ES), Universidad de Oviedo (ES)
Openalex Percentile: Top 42%
Anodic Oxide Films and Nanostructures
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.