Unlocking the potential of NH2-MIL-101 (Fe) nanoMOF for advanced electrochemical immunosensing in chronic wound diagnostics
In this work we take advantage, for the first time, of the porous and functional structure of a nanoscale metal organic framework (nanoMOF), specifically NH 2 -MIL-101 (Fe) nanoMOF, for its use as advantageous enzyme-carrier nanotag in immunoassays. In particular, the porous structure of the nanoMOF allows accommodating a high loading of enzyme molecules, which, in addition, are protected from degradation inside the pores providing a high stability. This property together with the ability of the nanoMOF to link antibodies through its functional groups make it a very robust and powerful label. Both the enhanced sensitivity, compared with the conventional use of enzyme-labelled antibodies, and the high long-term stability are demonstrated. Such nanotag also offers advantages related to ease of modification and cost effectiveness. The detection of myeloperoxidase (MPO), a key biomarker for chronic wound monitoring, is proposed to demonstrate the applicability of this approach. A sandwich-type immunoassay using magnetic beads (MBs)-based platforms and subsequent amperometric detection allows the determination of MPO in the clinical range (5 – 100 ng mL −1 ), with a limit of detection of 1.4 ng mL −1 , and good reproducibility (RSD (n = 10) = 7.1 %). The developed bio-strategy also exhibits high selectivity against potential interferents and a good stability of the nanotag for at least 2 months. Moreover, the developed method was successfully implemented to determine MPO in simulated chronic wound matrices, demonstrating its feasibility in a real scenario. • Novel tagging method for immunosensing exploiting a biomolecules decorated NH 2 -MIL-101 (Fe) nanoMOF. • Sandwich-type immunoassay for the amperometric determination of myeloperoxidase. • Sensitive (LOD of 1.4 ng mL −1 ) and selective determination of myeloperoxidase standards. • Threefold improvement in sensitivity compared to conventional sandwich immunoassay formats. • Successful analysis in simulated chronic wound matrices.
Authors
- Víctor Pérez‐Ginés
- José M. Pingarrón (ORCID: https://orcid.org/0000-0003-2271-1383)
- Alfredo de la Escosura‐Muñiz
- Susana Campuzano (ORCID: https://orcid.org/0000-0002-9928-6613)
- Francisco J. Garcı́a Alonso (ORCID: https://orcid.org/0000-0001-6911-1743)
- Rebeca M. Torrente‐Rodríguez (ORCID: https://orcid.org/0000-0002-2153-172X)
- David Valero‐Calvo (ORCID: https://orcid.org/0009-0005-4055-634X)
- Marı́a Pedrero (ORCID: https://orcid.org/0000-0002-2047-396X)
Institutions
- Universidad Complutense de Madrid (ES)
- Universidad de Oviedo (ES)
Publication Details
- Journal
- Sensors and Actuators B Chemical
- Published
- 2025-02-16
- DOI
- https://doi.org/10.1016/j.snb.2025.137460
- Citations
- 1
- Primary Topic
- Anodic Oxide Films and Nanostructures
- Type
- article
- Field-Weighted Citation Impact
- 0.52